English
3. WARNING LABEL
Do not use the Nailer with missing or damaged
WARNING LABEL.
A new WARNING LABEL is available from a
metabo HPT authorized service center.
Warning
label
4. Maintenance chart (See page 19)
5. Operator troubleshooting (See page 20)
6. Service parts list
A: Item No.
B: Code No.
C: No. Used
D: Remarks
CAUTION
Repair, modifi cation and inspection of metabo HPT
Power Tools must be carried out by a metabo HPT
Authorized Service Center.
This Parts List will be helpful if presented with the tool
to the metabo HPT Authorized Service Center when
requesting repair or other maintenance.
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
Maintenance chart
ACTION WHY HOW
Drain air line fi lter daily. Prevent accumulation of moisture
and dirt.
Open manual petcock.
Keep lubricator fi lled. Keep the Nailer lubricated. Fill with metabo HPT pneumatic tool
lubricant.
Clean fi lter element and blow air
through fi lter in direction opposite to
normal fl ow daily.
Prevent clogging of fi lter with dirt. Follow manufacturer’s instructions.
Clean magazine and feeder
mechanism.
Prevent a jam. Blow clean daily.
Keep push lever working properly. Promote operator safety and effi cient
Nailer operation.
Blow clean daily.
Lubricate the Nailer after nailing. Extend the Nailer life. Supply 5 – 10 drops of lubricant into
the Nailer.
Drain air compressor daily. Keep the Nailer operated properly. Open petcock on air compressor
tank.
MODIFICATIONS
metabo HPT Power Tools are constantly being
improved and modifi ed to incorporate the latest
technological advancements.
Accordingly, some parts (i.e. code numbers and/or
design) may be changed without prior notice.
SERVICE AND REPAIRS
WARNING
●
Only service personnel trained by
metabo HPT, distributor or employer shall
repair the Nailer.
●
Use only parts supplied or recommended by
metabo HPT for repair.
All quality Nailers will eventually require servicing or
replacement of parts because of wear from normal use.
NOTE: Specifi cations are subject to change without any
obligation on the part of metabo HPT.