Operating instructions

4 Description of control M200 / M210 (optional)
4/2
4.1.1 MIG/MAG welding task selection and operating point setting
(without option M210 / Program, one-dial operation operating mode)
Gas type
changeover
switch
Changeover switch for the various gas types
Wire electrode
diameter/
material type
changeover
switch
Selector switch for setting:
Wire electrode diameter and material for aluminium (Al)
Wire electrode diameter and material for high-alloy steel
(CrNi) or low-alloy steel (SG)
"Manual" position: Two-dial operation (no program pre-
selection)
Step switch
Welding speed selection
"Coarse" step
switch
For setting the welding speed in rough stages
1
12
11
10
9
86
5
4
3
2
"Fine" step
switch
For setting the welding speed in fine stages
0
m/min
2
4
6
8
-10
2
4
6
8
+10
15
201
5
10
Rotary dial
Rotary dial for setting:
1. Correction of wire feed speed (external scale) with
Program operating mode (one-dial operation)
2. Wire feed speed 1- 20m/min
(internal scale) for manual operating mode
(two-dial operation)