Instructions / Assembly

01
WS-300/A
14
Dear users:
Thanks for choosing our products, for the purpose of
safety, please read this manual carefully before use.
The instruction manual be the same with the fol-
lowing steam room:
WS-300/300A、
WS-301/301A、
WS-302/302A、
WS-303/303A、
WS-304/304A、
ATTENTIONS
1.It is recommended to fix a reliable leakage protector and earth line.
Test the leakage protector every time before use.
2.Drunk, high blood pressure, heart disease people are not allowed to
use this product, Children should be guided by adults.
3.Adjust the water temperature before taking shower, don't spray hot
water to your body. Steam outlet and drain pipe may be in high
temperature, keep away from them.
4.Watch out to advoid falling down when entering the steam room,
don't put hands into the door gap.
5.Please don't use hard wares to knock at the steam room.
6.Clean the tray after taking shower, to remove the soap or foam on
the tray.
7.If the glass seal separate from the door, please refix it to advoid
leaking water.
8.Use the tooth paste to clean the dirt on the tray.
9.Keep the tray clean to advoid blocking the drain.
10.Please don't hang heavy articles on the steam room or handrail.
11.After use, please turn off water and power supply, to advoid long
time working of the product.
12.Please dispose of the product according to the local law when it is
out of use.
13.Please contact the dealer if you have any problems.
TECHNIQUE PARAMETER
AC220V( ±10%)
50/60HZ
0.1~0.2Mpa
3KW
Voltage
Frequency
Water Volatge Power of steam generator
(VI) Telephone function (optional)
When the machine is turned on, the icon will flicker on the panel if there is an
incoming call; meanwhile, the speaker will play the ring tone. Touch the button
on the touch panel to answer the call, and the icon will stop flickering. Touch
the button on the touch panel again to end the call.
(VII) Failure Alarm Code
This machine has autonomous failure detection function. When the failure is
detected, the corresponding failure code will be displayed on the screen as
Failure Code
Failure Description
Countermeasure
Communication failure of steamer
cables
Inspect whether poor contact of the steamer
Cables occurs
Inlet valve failure
Drain valve failure
Failure of water inlet or drainage of
steamer
Water inlet failure of steamer
Temperature probe failure
Inspect the inlet valve and the connecting wires.
Inspect the drain valve and the connecting wires.
Insect the driving chip of the water inlet or drainage valve.
Inspect whether water failure occurs.
Inspect whether the probe wires are damaged or
poorlycontacted.
E1
E2
E3
E4
E5
E6
IV. Technical Parameters
Operation Conditions and Characteristics
Rated voltage
Rated current
Insulated resistor
Waterproof level
AC 220V
13.8A
>20M
IPX5
Rated frequency
Rated power
Current leakage
Current leakage protection
50Hz-60Hz
3050W
As per the enterprise
product inspection
standard
(15-30)mA
Load Configuration Parameters
Load type
Steam
Ceiling lamp
Background lamp
Ozone disinfection
Fan
Electromagnetic
Note1
valve
Speaker
Rated load voltage
Ac 220V
Ac 12V
Dc 12V
-----
Ac 12V
Ac 12V
Dc 12V
Rated load frequency
50Hz/60Hz
50Hz/60Hz
50Hz/60Hz
50Hz/60Hz
Rated load power
3kW
25W
5W
8/10W
5W
3W
5W
QTY
1
1
1
1
1
2
1
-----
-----
-----