116 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc.
USA
Internal Use Only—Beta Draft
Limits for Occupational/Controlled Exposure
Limits for General Population/Uncontrolled Exposure
Frequencies Blocked for Regulatory Compliance
802.11a frequencies 5.25-5.35 GHz and 5.47-5.725 GHz have been blocked for DFS compliance.
USA
Underwriters Laboratories
For the AP150 series, the AP200 series, the OAP180, and the RS4000, the following
statement and notices are applicable:
Frequency
Range (MHz)
Electric Field
Strength (E)
(V/m)
Magnetic
Field Strength
(H) (A/m)
Power Density
(S) (mW/cm2)
Averaging
Time |E|2,
|H|2 or S
(minutes)
1500-100,000 5 6
Frequency
Range (MHz)
Electric Field
Strength (E)
(V/m)
Magnetic
Field Strength
(H) (A/m)
Power Density
(S) (mW/cm2)
Averaging
Time |E|2,
|H|2 or S
(minutes)
1500-100,000 1.0 30
Note:
Occupational/controlled limits apply in situations in which persons are exposed as a con-
sequence of their employment provided those persons are fully aware of the potential for
exposure and can exercise control over their exposure. Limits for occupational/con-
trolled exposure also apply in situations when an individual is transient through a location
where occupational/controlled limits apply provided he or she is made aware of the
potential for exposure.
Note:
General population/uncontrolled exposures apply in situations in which the general pub-
lic may be exposed, or in which persons that are exposed as a consequence of their
employment may not be fully aware of the potential for exposure or can not exercise con-
trol over their exposure.