User's Manual
Table Of Contents
- Installing AP832e
- Installing AP832i
- Cautions and Warnings
- Regulatory Information
- Approved Antennas
- Regulatory Specifications
- AP832e/i
- USA
- Canada. Industry Canada (IC)
- Europe—EU Declaration of Conformity and Restrictions
- Japan
- Manufacturing Information
- AP Plenum Requirements
- Manufacturers Federal Communication Commission Declaration of Conformity Statement
- VCCI Statement for Japan
- Guidelines for Operating Meru AP832e and AP832i Access point
- Industry Canada
- EU Regulatory Conformance
- Declaration of Conformity with regard to the R&TTE Directive 1999/5/EC
- Declaration of Conformity for RF Exposure
- This Device Meets FCC Guidelines for Exposure to Radio Waves
- This Device Meets the Industry Canada Guidelines for Exposure to Radio Waves
- Maximum EIRP
- Dual Concurrent Same Band Operation
Regulatory Specifications
© 2013 Meru Networks, Inc. Regulatory Information xxxvii
Limits for Occupational/Controlled Exposure
Limits for General Population/Uncontrolled Exposure
Frequencies Blocked for Regulatory Compliance
802.11a frequencies 5.25-5.35 GHz and 5.47-5.725 GHz have been blocked for DFS
compliance.
This device uses 802.11a/b/g/n/ac standard with CCK and OFDM modulations. The
device shall automatically discontinue transmission in case of absence of information
to transmit or operation failure due the CCK and OFDM modulation and by turning off
the transmitter.
Frequency
Range (MHz)
Electric Field
Strength (E)
(V/m)
Magnetic
Field Strength
(H) (A/m)
Power Density
(S) (mW/cm2)
Averaging
Time |E|2,
|H|2 or S
(minutes)
1500-100,000 5 6
Frequency
Range (MHz)
Electric Field
Strength (E)
(V/m)
Magnetic
Field Strength
(H) (A/m)
Power Density
(S) (mW/cm2)
Averaging
Time |E|2,
|H|2 or S
(minutes)
1500-100,000 1.0 30
Note:
Occupational/controlled limits apply in situations in which persons are exposed as a
consequence of their employment provided those persons are fully aware of the potential
for exposure and can exercise control over their exposure. Limits for
occupational/controlled exposure also apply in situations when an individual is transient
through a location where occupational/controlled limits apply provided he or she is made
aware of the potential for exposure.
Note:
General population/uncontrolled exposures apply in situations in which the general
public may be exposed, or in which persons that are exposed as a consequence of their
employment may not be fully aware of the potential for exposure or can not exercise
control over their exposure.