Installation guide

Installation Requirements
© 2009 Meru Networks, Inc.Installing the AP150 43
Note:
The AP150 has two security cable slots (one on each side of the AP150) so you
can secure the AP150 with a standard security cable, such as those used to secure
laptop computers.
The following recommended mounting locations provide the best reception for the
AP150:
z On a horizontal surface, such as a table or a desk
z On a vertical surface, usually a wall
z Below a hanging ceiling
To complete this installation, you need the items listed in Tab le .
AP150 Installation Items
You need the tools listed below.
Caution!
The AP150 is not certified for plenum installations, and should not be installed
in the plenum space.
Installation Type Consumable Items Required
Horizontal mounting None
Vertical mounting over a wall stud
z Two #6 x 2" wood screws for a wood stud; or
z Two #6 x 1½" metal screws for a metal stud
z Mounting bracket
Vertical mounting on sheetrock
z Two #6 x 1" sc re w s
z Two #4-6 x 7/8" ribbed plastic wall anchors
z Mounting bracket
Horizontal mounting below a
hanging ceiling
z Two caddy fasteners
z Two plastic spacers
z Two keps nu t s ( w i t h at tached lock washer)
z Mounting bracket