User's Manual
7 / 84
© 2014 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
ENGLISH
Receiver
NOTICE
To keep the receiver free from debris, dirt, and humidity,
do NOT remove the receiver from the plastic bag until all
construction is complete.
1. Insert batteries or connect AC mains power. The mod-
ule for circulating fan and light/dimmer includes a mains
adapter. With mains adapter, batteries can be used for
backup (RF only).
ON position.
3. The receiver has to learn the handset code:
page 8) until you hear two (2) beeps. After the second,
longer beep, release the reset button. Within the subse-
code is set.
NOTE:
when changing the batteries in the handset or re-
ceiver.
4. Check the reception. For better reception straighten the
antenna
and move it to a position
that allows for better reception (see notice below).
5. When the RF-receiver is placed in the appliance, the sur-
rounding metal can reduce reception considerably. The
reception.
NOTICE
The antenna must not cross or come into contact with
the ignition wire. This will render the receiver inoperable.
IR Versions
Place the infrared eye in a suitable position. The infrared
V Module
-
wires with core cable ends to the pluggable screw terminals.
2
-
ure 11, page 9).
supply.
ELECTRIC SHOCK HAZARD
could result in property damage, personal injury, or loss
of life.
accordance with all codes and local regulations. Service
and installation must be performed by a trained, experi-
enced service technician.
NOT use the module if you suspect it may be damaged.
PERFORM GAS LEAK TEST
1. Check carefully for gas leaks immediately after the valve
has been installed and the gas turned on. Do this be-
fore attempting to operate the appliance or other gas
burning device.
2. Use an approved -
er approved leak detection method, around the diaphragm
Bubbles indicate a leak.
3. If no leakage is detected, light the main burner.
4. With the main burner in operation, apply an approved leak test
solution to all tubing and pipe connections (including adapt-
ers) and the valve inlet and outlet. Bubbles indicate a leak.
5. If a leak is detected, tighten pipe connections (including
adapters) according to “GAS CONNECTIONS” (page 6).
Absolutely no leakage should occur, otherwise there is a
Never use if leakage is detected.
WIRING CONNECTIONS
NOTICE
Wiring of valve and receiver must be completed before start-
ing ignition. Failure to do so could damage the electronics.
-
ing diagram.
not exposed to dirt, oil, grease or other chemical agents.
NOT permit foreign particles under plastic cover.
-
cessible for the user.
Thermocouple Circuit
Total resistance of thermocouple circuit should be minimized
to ensure proper operation.
NOTICE
The use of the Mertik Maxitrol interrupter block is rec-
ommended. Keep connection of interrupter block and
thermocouple clean and dry. Avoid severe bending of the
thermocouple tubing during installation (min. 1” radius;
2.5 cm) as this may cause it to fail.
tight (2...3 Nm).
(2...3 Nm).
Ignition Cable
Do NOT damage the ignition cable while attaching it to the
ignition electrode. When the cable is in place, avoid contact
with sharp objects or edges. With cables longer than 900 mm,
avoid contact with metal parts, as this could decrease spark.
NOTICE
INSTALLATION INSTRUCTIONS FOR OEM USE ONLY