User's Manual

20 / 84
© 2014 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
ENGLISH
OPERATING INSTRUCTIONS FOR OEM USE ONLY
1. STOP! Read the safety information included before pro-
ceeding.
2. Turn main valve knob to the OFF, full clockwise
position.
3. Turn MANUAL knob to the MAN, full clockwise
po-
sition.
4. Place ON/OFFO (OFF position).

gas is in the area around the appliance, including near
 If you detect gas STOP! Follow “WHAT TO
DO IF YOU SMELL GAS” in the safety information on
page 2. If no gas is present, proceed to step 6.
6. Place ON/OFFI (ON position).
7. With the MANUAL knob in MAN position a manual pilot
valve operator and piezo ignitor (optional) are accessible.
8. Fully push down manual pilot valve operator and hold in,

IGNITION WITH MATCH:
Immediately light the pilot with a match, while continuing
to hold in the manual pilot valve operator for about one
(1) minute after the pilot is lit. Release manual pilot valve

repeat.
IGNITION WITH PIEZO IGNITOR:
Change the ignition cable from the receiver to the valve


If the pilot does not stay lit after several tries, turn the main
valve knob to OFF and proceed to step 12.
9. If applicable, replace pilot access panel before proceed-
ing.
10. Turn MANUAL knob to the ON, full counter-clockwise
position.
11. Turn main valve knob to the full ON, full counter-clock-
wise
position.
12. If the appliance will not operate, follow the instructions
“TURN OFF GAS TO APPLIANCE”.
TO TURN OFF GAS TO APPLIANCE
O (OFF position).
2. If gas control is accessible turn main valve knob to the
OFF full clockwise
position.
AUTOMATIC TURN DOWN
6 Hour no Motor Movement
(CSA version)
     

a 6 hour period. In Temperature/Timer Mode if the ambi-


continue to function normally. The valve will turn to pilot
        -
perature remain the same over a 6 hour period.
Figure 24: Combination control, cover
8 Wire
Receiver jack
Micro switch
MANUAL knob
in MAN position
Main valve knob
in OFF position
Manual pilot
valve operator
Piezo ignitor
(optional)
ON/OFF switch
(optional) in
ON Position
Connection
piezo ignitor
tab 2.8 x 0.8 mm
Receiver Overheating
(only if module is connected)

is higher than 140 °F (60 °C). The main burner comes back
on only when the temperature is below 140 °F (60 °C).
1 Hour Turn Down for Special Receiver

  

AUTOMATIC SHUT OFF
Low Battery Receiver


is interrupted.
Five Day Shut Off
(CSA version)
          

Second Thermocouple Shut Off
(optional)

completely ignite approximately 20 seconds after ignition
or after pushing the

NOTE: Before the next ignition there is a 2 minute waiting
period.
If the thermocouple is still too hot, then you
will hear a long beep.