Users Manual Part 2
22 / 30
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY
© 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
TECHNICAL DATA
AMBIENT TEMPERATURE RANGE
CSA: The Puck: 32 °F to 131 °F
CE: The Puck: 0 °C to 55 °C
RADIO FREQUENCY
CSA: 918.0 MHz for U.S. (FCC), Canada (ISED), New Zea-
land (RNZ) and Australia (ACMA) (The Puck, receiver)
CE: 868.1 MHz for Europe (The Puck, receiver)
(see radio frequency information on page 4.)
RADIATED POWER OUTPUT
CSA: 84.5 µV/m
CE: -18.5 dBm
POWER SUPPLY
Handset: 2 x 1.5 V “AAA” (quality alkaline recommended)
NOTICE
Wiring of valve and receiver must be completed before starting
ignition. Failure to do so could damage the electronics.
NOTICE
The handsets and receivers are not interchangeable with previ-
ous electronics G6R and B6R-R8(9)U(T).
To avoid damaging the electronics, do NOT use metal tools to
remove the batteries from the handset / receiver.
▪ Without using a mains adapter, battery replacement is recom-
mended at the beginning of each heating season.
▪ Old or dead batteries should be removed immediately. If left
in the unit the batteries can overheat, leak, and / or explode.
▪ Do NOT expose batteries (including during storage) to direct
sunlight, excessive heat, re, moisture, or severe impact. Each
of these conditions can cause the batteries to overheat, leak,
and / or explode.
▪ Batteries must be kept within their recommended temperature
limits (ambient battery temperature range: 32 °F to 131 °F /
0 °C to 55 °C).
▪ New and old batteries and different brands of batteries should
not be used together. Mixing of various batteries can cause
the batteries to overheat, leak, and / or explode.
ON / OFF
Up / HIDown /LO
Figure 23: 3-button layout
THE PUCK HANDSET
SYNCHRONIZATION RECEIVER / THE PUCK HANDSET
NOTICE
See page 7 for more information about synchronization between
receiver and The Puck.
MODES OF OPERATION
When pilot ignition is conrmed, motor turns automatically to
maximum ame height.
TURN FIRE ON AND OFF
▪ Press and hold the
button until two
short beeps conrms the start se-
quence has begun; release button.
▪ Main gas ows once pilot ignition is
conrmed.
▪ Press and hold the
button to turn
OFF
.
If the pilot does not stay lit after several tries, turn the main valve
knob to OFF and follow the instructions “TURN OFF GAS TO
APPLIANCE” (see page 10).
STANDBY MODE (PILOT FLAME)
▪ Press and hold the "–" button to set
appliance to pilot ame
FLAME HEIGHT ADJUSTMENT
▪ To increase ame height press and
hold "+" button.
▪ To decrease ame height or to set ap-
pliance to pilot ame, press and hold
"–" button.
DESIGNATED LOW FIRE AND HIGH FIRE
▪ To go to hi re, double-click "+" button.
▪
To go to low re, double-click "–" button.
NOTE: Flame goes to high re rst be-
fore going to low re.
If the appliance will not operate, follow the instructions “TURN
OFF GAS TO APPLIANCE”
(see page 10)
.