Users Manual Part 2

27 / 30
ENGLISH
INSTALLATION AND OPERATING INSTRUCTIONS DR AFT FOR OEM USE ONLY
© 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
1 2 1 2
1 2
1 2 1 2
1 2
Hand tighten M4 screws (not provided) to secure the module via the two pre-drilled screw holes.
Use only M4 screws to secure the module.
Figure 29
Max. AWG 12 / 2.5 mm
2
Receiver
B6R-R8P,
B6R-RAP
FAN, LIGHT / DIMMER, 2ND BURNER FEATURE
V Module G6R-BEAV3
ELECTRIC SHOCK HAZARD
Read these instructions carefully. Failure to follow them could result in property damage, personal
injury, or loss of life.
This control must be electrically wired and operated in accordance with all codes and local regula-
tions. Service and installation must be performed by a trained, experienced service technician.
Do not use the module if you suspect it may be damaged.
4 levels from
60 % to 100 %
14 to 100 Watt
The appliance
manufacturer must
test levels with fan.
Levels may vary
with fan
characteristics.
Innitely variable
20 % to 100 %
0 to 100 Watt
NOTE: To connect
LED lights or 12 V
lamps a driver/
transformator is
needed.
Latching Solenoid Valve
GV-S60…
(Latching solenoid as
shown shuts off burner 2,
leaving on the burner 1.
For more information see
instructions
GV-S60-II-EN.DE.FR.NL…
or consult Mertik Maxitrol.)
Cable V Module-Receiver
G6R-CBV…
V Module G6R-BUMV3
Molex 39-01-4031
Molex 39-01-4041
Combination Control
GV60…
Mains Power
(115 / 230 V; AC)
NOTICE