Users Manual Part 1

4 / 30
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY
© 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
GENERAL RADIO FREQUENCY INFORMATION
Amendment: This device complies with Part 15 of the FCC Rules.
The device contains licence-exempt transmitter(s) / receiver(s)
that comply with Innovation, Science and Economic Develop-
ment Canada's licence-exempt RSS(s). Operation is subject to
the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including inter-
ference that may cause undesired operation of the device.
Changes or modications not expressly approved by the party
responsible for compliance could void the user’s authority to
operate the equipment. To satisfy ISED exposure requirements
a separation distance of 20 cm or more should be maintained
between the antenna of this device and persons during op-
eration. To ensure compliance, operations at closer distances
than this are not recommended.
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential instal-
lation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interfer-
ence will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one
or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Consult the dealer or an experienced radio / TV technician for
help.
Compliant with the EU-Radio Equipment Directive 2014/53/EU
(RED).
It is the appliance manufacturer’s responsibility to determine
GV60’s suitability for a specic application.
Do NOT remove screws from the gas valve. Do NOT adjust
and / or alter any components marked with tamper indicating
paint. Motor knob is not to be removed.
1. Turn off gas supply at the appliance service valve before
starting installation, and perform a Gas Leak Test after the
installation is complete.
2. Install the sediment trap or lter (where required) in the gas
supply line to prevent contamination of the gas valve (see
gure 8, page 5).
3. Use only your hand to push in or turn the gas control knobs.
Never use tools. If a knob will not push in or turn by hand,
do not try to repair it. Call a qualied service technician.
Force or attempted repair will void warranty and can result
in a re or explosion.
TECHNICAL DATA
APPROVALS
CSA: Multifunctional gas control according to ANSI Z21.78
6.20 and ANSI Z21.20 6.20 for U.S. & Canada
CE: Gas Appliances Regulation 2016/426/EU and DIN EN
298, DIN EN 126, DIN EN 13611, 2014/53/EU (RED)
FUELS
CSA: Suitable for natural, manufactured, mixed gases, lique-
ed petroleum gases, and LP gas-air mixtures.
CE: Suitable for use with gases of EN 437 gas family 1, 2 and 3.
PRESSURE DROP / CAPACITY
CSA: @ 1" w.c. at 65,000 BTU / hr for 0.65 s.g. natural gas
CE: 2.5 mbar (0.25 kPa) at 1.2 m³ / h air
RANGE OF REGULATION
CSA: 10,000 to 85,000 BTU / hr
CE: Class C according EN 88
REGULATOR ADJUSTMENT
CSA: 3" w.c. to 5" w.c.; 8" w.c. to 12" w.c.
Convertible Regulator: 3 to 4.5" NG / 8.5 to 11.5" LP
CE + CSA: 3" w.c. to 12" w.c. (7.5 to 30 mbar)
CE: 5 to 40 mbar (0.5 to 4 kPa)
MAXIMUM INLET PRESSURE
CSA: ½ psi (14" w.c.)
CE: 50 mbar (5 kPa)
MAIN GAS CONNECTION
CSA: NPT (ANSI / ASME B1.20.1)
CE: Rp (ISO 7-1 / EN 10226-1), compression ttings for
8 mm, 10 mm or 12 mm tube
PILOT GAS CONNECTION
CSA: 7 / 16-24 UNS for ¼" or
3
/
16
" tubing
CE: M10x1 for 4 mm or 6 mm tubing
INLET AND OUTLET CONNECTION
Side or Bottom
MAXIMUM ALLOWED TORQUE
- INLET, OUTLET, LATCHING SOLENOID ⅜"
CSA: 280 inch-pounds
CE: 35 Nm
- LATCHING SOLENOID 8 mm tube
CE: 20 Nm
- PILOT GAS CONNECTION
CSA: 100 inch-pounds
CE: 15 Nm
THERMOCOUPLE / INTERRUPTER BLOCK
11 / 32-32 UNS, M10x1, M9x1, M8x1
AMBIENT TEMPERATURE RANGE
CSA: Combination Control: 32 °F to 176 °F
Latching Solenoid Valve: 32 °F to 176 °F
Misc. cables: 221 °F
Relay with Cable: 158 °F
CE: Combination Control: 0 °C to 80 °C
Latching Solenoid Valve: 0 °C to 80 °C
Misc. cables: 105 °C
Relay with Cable: 70 °C
GV60 – GAS COMBINATION CONTROL