Users Manual Part 2

20 / 29
INSTALLATION AND OPERATING INSTRUCTIONS FOR OEM USE ONLY
© 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
DRAFT 21/11/2018
SELECTED
1 2
ON
AM
PM
OFF
ON TIME SETTING (PROGRAM 1):
7.
, , displayed, is displayed
shortly, and hour ashes.
8. To select hour press
or button.
9. To conrm press
button. , ,
displayed, displayed shortly,
and minutes ash.
10. To select minutes press
or but-
ton.
11. To conrm press
button.
OFF TIME SETTING (PROGRAM 1):
1 2
ON
AM
PM
OFF
12. , ,
displayed, is displayed
shortly, and hour ashes.
13. To select hour, press
or button.
14. To conrm press
button. , ,
displayed, displayed short-
ly, and minutes ash.
15. To select minutes press
or but-
ton.
16. To conrm press
button.
NOTE: Either continue to PROGRAM 2 and set on and off times
or stop programming at this point, and PROGRAM 2 re-
mains deactivated.
NOTE: PROGRAM 1 and 2 use the same on (Thermostatic) and
off temperatures for
, and Daily Timer (  , , ,  ,  ,
 , ). Once a new on (Thermostatic) and / or off tempera-
ture has been set, that temperature becomes the new
default setting.
NOTE: If
, or Daily Timer are programmed for PRO-
GRAM 1 and PROGRAM 2 on and off times, these be-
come the new default times. The batteries must be re-
moved to clear the PROGRAM 1 and PROGRAM 2 on
and off times and temperatures.
or Daily Timer (  , , ,  ,  ,  , ) selected
Set on time and off time using same procedure as
se-
lected” (above).
:
Set on time and off time for both Saturday and Sunday.
Daily Timer: Unique on and off times may be set for a single
day of the week, for multiple days of the week, or for every day
of the week.
Wait to nish setting.
AUXILIARY FEATURE (2ND BURNER FEATURE)
The latching solenoid valve will open automatically after ignition
or after switching the system off, so that the maximum ow of
gas is supplied to both burners assisting with the ignition pro-
cess. After pressing the AUX-button the motor will turn 7 sec-
onds in the ON direction until the max. position is reached.
1 2
ON
AM
PM
OFF
ON:
To switch a burner on, press the but-
ton. displayed.
OFF:
To switch the burner off, press the
button.
disappears.
NOTE: The latching solenoid valve cannot operate manually. If
the receiver battery runs down it will remain in the last
operating position.
ECO MODE
AM
ON:
Press
button to enter Eco Mode.
displayed.
OFF:
Press
button. disappears.
CIRCULATING FAN OPERATION
AM
Circulating fan has 4 speed levels from
low (1 bar) to high (4 bars).
SETTING:
1. Press
button and hold until
ashes.
2. Press
button to increase fan speed
and
button to decrease fan speed.
3. To conrm setting either press
but-
ton or wait (
displayed).
OFF:
Press
button until all 4 speed level
bars disappear.
NOTE: SETTING only. If the fan was not switched off after last
use, it starts automatically 4 minutes after ignition at max-
imum speed and goes to the last set level after 10 sec-
onds. The fan stops 10 minutes after the gas is OFF or
at pilot.