Users Manual Part 1

18 / 29
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY
© 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
MANUAL MODE (HANDSET)
NOTICE
BEFORE OPERATING
1. Make sure MANUAL knob on the GV60 valve is in the ON,
full counterclockwise
position.
2. Place the ON / OFF switch (if equipped) in the I (ON) position.
TO TURN ON FIRE
When pilot ignition is conrmed, motor turns automatically to
maximum ame height.
1 2
ON
AM
PM
OFF
Press button (One Button Ignition)
or
and button simultaneously
(Two Button Ignition) until two short
beeps and a blinking series of lines
conrms the start sequence has be-
gun; release button(s).
Main gas ows once pilot ignition is
conrmed.
Handset automatically goes into Man-
ual Mode after main burner ignition.
If the pilot does not stay lit after several tries, turn the main valve
knob to OFF and follow the instructions “TURN OFF GAS TO
APPLIANCE” (see page 9).
STANDBY MODE (PILOT FLAME)
Handset
Press and hold
button
to set appliance to pilot ame.
TO TURN OFF FIRE
1 2
ON
AM
PM
OFF
Handset
Press
button to turn off
.
NOTE: A new ignition is possible after
the OFF icon stops ashing.
FLAME HEIGHT ADJUSTMENT
1 2
ON
AM
PM
OFF
Handset
To increase ame height press and
hold
button.
To decrease ame height or to set ap-
pliance to pilot ame, press and hold
button.
DESIGNATED LOW FIRE AND HIGH FIRE
NOTE: Backlight must be on for high re and low re double-click
operation.
AM
To go to low re, double-click but-
ton.
is displayed.
NOTE: Flame goes to high re rst be-
fore going to low re.
AM
To go to high re, double-click but-
ton.
is displayed.
If the appliance will not operate, follow the instructions “TURN
OFF GAS TO APPLIANCE
(see page 9)
.
COUNTDOWN TIMER
1 2
ON
AM
PM
OFF
ON / SETTING:
1. Press and hold button until dis-
played, and hour ashes.
2. To select hour press or button.
3. To conrm press
button. Minutes
ash.
4. To select minutes press
or button.
5. To conrm press
button or wait.
OFF:
Press
button,
and Countdown Time
disappear.
NOTE: At end of Countdown Time period, the re shuts off. The
Countdown Timer only works in Manual, Thermostatic,
and Eco Modes. Maximum Countdown Time is 9 hours
and 50 minutes.