Users Manual Part 1
11 / 29
ENGLISH
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY
© 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
TOUCHPAD / WALL SWITCH
Increase ame height
ON / OFF
Decrease ame height
Figure 19: Touchpad / Wall Switch
AMBIENT TEMPERATURE RANGE
CSA: Wall Switch / Touchpad: 176 °F
CE: Wall Switch / Touchpad: 80 °C
To Turn ON Appliance
▪ Press
button (see gure 19, page 11) until two short
beeps conrm the start sequence has begun; release button.
▪ Once pilot ignition is conrmed, there is main gas ow.
If the pilot does not stay lit after several tries, turn the main
valve knob to OFF and follow the instructions “TO TURN OFF
GAS TO APPLIANCE” (see page 10).
Flame Height Adjustment
▪ Press and hold
(large ame) button to increase ame height.
▪ Press and hold
(small ame) button to decrease ame height
or to set appliance at pilot ame.
Standby Mode (Pilot Flame)
▪ Press and hold
(small ame) button to set appliance at pilot ame.
To Turn OFF Appliance
If the appliance will not operate, follow the instructions “TO
TURN OFF GAS TO APPLIANCE”
(see page 10)
.
▪ Press button.
TO OPEN AND CLOSE SOLENOID VALVE / BURNER
▪ Simultaneously press the
and (small ame) buttons
to switch the decorative burner OFF.
▪ Simultaneously press
and (large ame) buttons but-
tons to switch decorative burner on.
NOTE: The latching solenoid valve cannot operate manually. If
the receiver battery runs down it will remain in the last
operating position.
SWITCH PANEL
Figure 20: Switch Panel
A) Increase ame height
B) ON / OFF
C) Decrease ame height
AMBIENT TEMPERATURE RANGE
CSA: Switch Panel: 221 °F
CE: Switch Panel: 105 °C
To Turn ON Appliance
▪ Press “B” button (see gure 20, page 11) until two short beeps
conrm the start sequence has begun; release button.
▪ Once pilot ignition is conrmed, there is main gas ow.
If the pilot does not stay lit after several tries, turn the main
valve knob to OFF and follow the instructions “TO TURN OFF
GAS TO APPLIANCE” (see page 10).
Flame Height Adjustment
▪ Press and hold “A” button to increase ame height.
▪ Press and hold “C” button to decrease ame height or to set
appliance at pilot ame.
Standby Mode (Pilot Flame)
▪ Press and hold “C” button to set appliance at pilot ame.
To Turn OFF Appliance
If the appliance will not operate, follow the instructions “TO
TURN OFF GAS TO APPLIANCE”
(see page 10)
.
▪ Press “B” button.
TO OPEN AND CLOSE SOLENOID VALVE / BURNER
▪ Simultaneously press the “B” and “C” buttons to switch the dec-
orative burner OFF.
▪ Simultaneously press “B” and “A” buttons buttons to switch
decorative burner on.
NOTE: The latching solenoid valve cannot operate manually. If
the receiver battery runs down it will remain in the last
operating position.