User Instructions Part 2

OPERATING INSTRUCTIONS FOR OEM USE ONLY
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
28 / 28
MANUAL OPERATION
(Only possible, when MANUAL knob is used)
Access to the pilot burner is only required for ignition with a match.
When turning main valve knob, do not force. Knob has a slip
clutch that clicks until the end stops are reached. This allows for
manual fl ame height adjustment as well as adjustment to pilot
standby position.
1. STOP! Read the safety information included before proceeding.
2. Turn main valve knob to the
OFF
, full clockwise position.
3. Turn MANUAL knob to the
MAN
, full clockwise position.
4. Place ON/OFF switch (if equipped) in O (OFF position).
5. Wait fi ve (5) minutes to clear out any gas. Verify that no gas
is in the area around the appliance, including near the fl oor.
If you detect gas STOP! Follow “WHAT TO DO IF YOU
SMELL GAS” in the safety information on page 2. If no gas
is present, proceed to step 6.
6. Place ON/OFF switch (if equipped) in “
I
” (ON position).
7. With the MANUAL knob in
MAN
position a manual pilot valve
operator and piezo ignitor (optional) are accessible.
8. Fully push down manual pilot valve operator and hold in, to
start pilot gas fl ow (see fi gure 25).
Ignition with match:
Immediately light the pilot with a match, while continuing to
hold in the manual pilot valve operator for about one (1) minute
after the pilot is lit. Release manual pilot valve operator. If pilot
does not stay lit, wait fi ve (5) minutes and repeat.
Ignition with piezo ignitor:
Change the ignition cable from the receiver to the valve (see
fi gure 25). Push in the piezo ignitor to ignite. If pilot does not
stay lit, wait fi ve (5) minutes and repeat.
If the pilot does not stay lit after several tries, turn the gas
control knob (main valve knob) to OFF and proceed to step 12.
Figure 25: Combination control, cover
8 Wire
Receiver jack
Microswitch
MANUAL knob
in MAN position
Main valve knob
in OFF position
Manual pilot
valve operator
Piezo ignitor
(optional)
ON/OFF switch
(optional) in
ON Position
Connection
piezo ignitor tab
2.8 x 0.8 mm
9. If applicable, replace pilot access panel before proceeding.
10. Turn MANUAL knob to the
ON
, full counterclockwise
position.
11. Turn main valve knob to the full
ON
, full counterclockwise
position.
12. If the appliance will not operate, follow the instructions “TO
TURN OFF GAS TO APPLIANCE” (below).
TO TURN OFF GAS TO APPLIANCE
1. Place ON/OFF switch (if equipped) in
O (OFF position).
2. If gas control is accessible turn main valve knob to the OFF full
clockwise
position.
3. Replace appliance access cover (if applicable).
AUTOMATIC TURN DOWN
3 Hour No Communication Function
▪ The valve will turn to pilot fl ame if there is no communication
between handset and receiver for a 3 hour period. The fi re will
continue to function normally when communication is restored.
Receiver Overheating
(only if module is connected)
▪ Valve turns to pilot fl ame if the temperature in the receiver is
higher than 140 °F (60 °C). The main burner turns back ON
(manually or in thermostatic mode) only when the temperature
is below 140 °F (60 °C).
1 Hour Turn Down for Special Receiver
(bedroom fi replaces only)
▪ The valve will turn to pilot fl ame if there is no change in fl ame
height over a 1 hour period.
AUTOMATIC SHUT OFF
Countdown Timer
▪ At end of countdown time period, the fi re turns OFF. The Count-
downTimer only works in Manual, Thermostatic, and Random
modes. Maximum countdown time is 9 hours.
Low Battery Receiver
▪ With low battery power in the receiver the system shuts off the
fi re completely. This will not happen if the power supply is inter-
rupted.
Five Day Shut Off
(CSA version)
▪ The system shuts off the fi re completely if there is no change in
fl ame height for 5 days.
2
nd
Thermocouple Shut Off
▪ 2
nd
thermocouple Option: The system shuts OFF the fi re if the
main burner does not completely ignite approximately 20 sec-
onds after ignition or after pushing
button.
NOTE: Before the next ignition there is a 2 minute waiting period.
Exclusive Distributor North America for Mertik Maxitrol
Maxitrol Company, Inc.
23555 Telegraph Rd., PO Box 2230,
Southfield, MI 48037-2230, USA
Tel: +1 248-356-1400, Fax: +1 248-356-0829
www.maxitrol.com
Mertik Maxitrol GmbH & Co. KG
Warnstedter Str. 3, 06502 Thale, Germany
Tel: + 49 3947 400-0, Fax: + 49 3947 400-200
www.mertikmaxitrol.com
R
R
GV60-II.OI-EN-10.2013-Symax