User Instructions Part 1
INSTALLATION INSTRUCTIONS FOR OEM USE ONLY
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
8 / 28
1 2
1 2 1 2
1 2
1 2 1 2
1 2 1 2
1 2
1 2 1 2
1 2
1 2 1
2
1 2
1 2
1 2
1 2
Figure 11
Receiver
B6R-R9(8)U...
GV60 Valve
Cable V Module-Receiver
G6R-BU(E)SV2
G6R-BU(E)MV2
Molex 39-01-4031
Molex 39-01-4041
Max. AWG 12/2,5 mm
2
ELECTRIC SHOCK HAZARD
▪ Read these instructions carefully. Failure to follow them could result in property damage, personal
injury, or loss of life.
▪ This control must be electrically wired and operated in accordance with all codes and local regula-
tions. Service and installation must be performed by a trained, experienced service technician.
▪ Do not use the module if you suspect it may be damaged.
4 levels from
60 % to 100 %
14 to 100 Watt
The appliance
manufacturer must
test levels with fan.
Levels may vary
with fan
characteristics.
Infi nitely variable
20 % to 100 %
14 to 100 Watt
Not for LED and
not for energy
saving lamp.
This outlet can be used for differnet functions
depending on handset:
Handset Function
B6R-H8(9)D6 Powerfl ue
B6R-H8(9)T5 Powerfl ue
B6R-H8(9)
TV14
Powerfl ue
B6R-H8(9)TV4 Relay, Latching Solenoid
Valve (AUX), see fi gure 13,
page 10
Latching Solenoid
Valve
Latching solenoid as
shown shuts OFF
burner 2, leaving the
burner 1, ON.
For other options con-
sult Mertik Maxitrol.
ADDITIONAL FUNCTION RF: FAN – LIGHT/DIMMER – LATCHING SOLENOID