User Instructions Part 1

INSTALLATION INSTRUCTIONS FOR OEM USE ONLY
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
7 / 28
ON-OFF
UP
DOWN
Figure 10
BASIC RF
Pilot Burner
Wall Switch
(Optional)
Receiver
B6R-R9(8)A...
or
B6R-R9(8)U...
or
B6R-R9(8)K...
Thermocurrent Cable SW
with ON/OFF Switch
Thermocurrent Cable TC
8 Wire Cable
Interrupter Block
Mains Adapter
(Optional)
Ignition Cable
RESET Button
GV60 Valve
Wall Switch
Wall Switch
(Optional)
(Optional)
Mains Adapter
Mains Adapter
(Optional)
(Optional)
RESET Button
In addition to the basic version, a universal receiver, B6R-R8,9U(T), can be used to operate a second
burner, a relay (3pin outlet), or to start a power ue control (2pin outlet). The same receiver outlet
(3pin) is used for these functions, and the transmitter activates the function. Together with a module,
the universal receiver, B6R-R8,9U, controls a circulating fan and a dimmer.
The receivers B6R-R9(8)U and B6R-9(8)K have main burner supervision (2nd thermocouple option).
For safety, this option is programmed so that it cannot be used without the second thermocouple
installed and vice versa.
Main Burner