User Instructions Part 1

INSTALLATION INSTRUCTIONS FOR OEM USE ONLY
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
4 / 28
Misc. cables: 221 °F
Cable with relay: 158 °F
CE: Combination control: 0 °C to 80 °C
Latching solenoid valve: 0 °C to 80 °C
Receiver RF without batteries: 80 °C
Receiver RF with batteries: 60 °C
Handset: 60 °C
Wall switch/touch pad: 80 °C
Switch panel: 105 °C
Module: 80 °C
Ignition cable: 150 °C
HANDSETS
NOTICE
The handsets and receivers are not interchangeable with previ-
ous electronics (see fi gure 7).
RADIO FREQUENCY
868 MHz for Europe
915 MHz for U.S. and for Canada.
This device complies with Part 15 of the FCC Rules and with
Industry Canada license-exempt RSS standard(s). Opera-
tion is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) This device must
accept any interference received, including interference that
may cause undesired operation. Changes or modifi cations not
expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential instal-
lation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interfer-
ence will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one
or more of the following measures: Reorient or relocate the
receiving antenna.
BATTERIES – HANDSET
2 x 1.5 V “AAA” (quality alkaline recommended).
BATTERIES – RECEIVER
4 x 1.5 V “AA” (quality alkaline recommended).
An AC Mains Adapter may be used instead of batteries.
NOTICE
Only the Mertik Maxitrol AC Mains Adapter or one preapproved
by Mertik Maxitrol can be used. Use of other adaptors can
render the system inoperable.
V MODULE
CE: Inlet: 230 VAC/50 Hz; 210 VA
Outlet: 230 VAC/50 Hz; 100 VA each
Built-in fuse 2,5 A
CSA: Inlet: 115 VAC/60 Hz; 210 VA
Outlet: 115 VAC/60 Hz; 100 VA each
Built-in fuse 2.5 A
TECHNICAL SPECIFICATIONS
Gas combination control according to CSA or CE approval
(see label for certifi cation)
APPROVALS
CSA: Multifunctional gas control according to ANSI Z21.78
6.20 and ANSI Z21.20 6.20 for U.S. & Canada
CE: Gas Appliances Directive 90/396/EEC and EN 298-2003,
DIN EN 126
FUELS
CSA: Suitable for natural, manufactured, mixed gases, lique-
ed petroleum gases, and LP gas-air mixtures.
CE: Suitable for use with gases of EN 437 gas family 1, 2
and 3.
PRESSURE DROP/CAPACITY
CSA: 1” w.c. at 65,000 BTU/hr
CE: 2,5 mbar at 1,2 m³/h air
RANGE OF REGULATION
CSA: 10,000 to 85,000 BTU/hr
CE: Class C according EN 88
REGULATOR ADJUSTMENT
CSA: 3” w.c. to 5” w.c.; 8” w.c. to 12” w.c.
CE: 5 to 40 mbar (50 to 400 kPa)
CE + CSA: 3” w.c. to 12” w.c. (7.5 to 30 mbar)
Convertible Regulator: 3 to 4.5” NG/8.5 to 11.5” LP
MOUNTING POSITION
In upright position, gas control knobs are on top of the valve.
Valve may be mounted 0° to 90° any direction (including verti-
cal) from the upright position. Valve must NOT be mounted
upside down.
MAXIMUM INLET PRESSURE
CSA: ½ psi (14” w.c.)
CE: 50 mbar (5 kPa)
MAIN GAS CONNECTION
CSA: ⅜ NPT (ANSI/ASME B1.20.1), ⅜ Loxit
CE: Rp (ISO 7-1/EN 10226-1), compression ttings for
8 mm, 10 mm or 12 mm tube
PILOT GAS CONNECTION
CSA: 7/16-24 UNS for ¼” or
3
/
16
” tubing
CE: M10x1 for 4 mm or 6 mm tubing
INLET AND OUTLET CONNECTION
Side or Bottom
MAXIMUM ALLOWED TORQUE INLET AND OUTLET
CSA: 280 inch-pounds
CE: 35 Nm
THERMOCOUPLE/INTERRUPTER BLOCK
11/32-32 UNF, M10x1, M9x1, M8x1
AMBIENT TEMPERATURE RANGE
CSA: Combination control: 32 °F to 176 °F
Latching solenoid valve: 32 °F to 176 °F
Receiver RF without batteries: 176 °F
Receiver RF with batteries: 140 °F
Handset: 140 °F
Wall switch/touch pad: 176 °F
Switch panel: 221 °F
Module: 176 °F
Ignition cable: 302 °F
Figure 7: Previous Handsets