3. Operation
3.1 Transport Mode
They are shipped with batteries inside the sensor. Default the sensor is in transport mode which means not to activate
operation.
3.2 Installation Mode
Users need to press the button over 5 seconds to activate operation into installation mode. When the Sensor
tries to join the network, it will keep blinking for 3 seconds.
Once the sensor joins the network, the LED will keep on for 3 seconds and send an uplink.
Users can press the button for over 5 seconds to try to join the network again.
The device will send uplink three times with FW version when the device joined successfully.
3.3 Default Operation
● During default operation the device will send a message to the network anytime there is a sufficient delta in the
environmental conditions
○ Water leakage status change dry/wet (dry to wet Buzzer alarm)
○ Tamper detected (Buzzer alarm)
○ Button pressed (No buzzer alarm)
○ Keepalive message (No buzzer alarm).
● Users can press the button to send a test message to the network.
● The device will send a message saying it has been inactive for 60 minutes.
● While in default mode the device will flash the LED 3 times within 100ms only when the user presses the test
button.