Operating instructions

9
Install Guide
BUILT IN INSTALLATION GUIDE
The Merrychef 402s is primarily designed for
counter top installation and is not recommended
for built-in enclosures. Should it be necessary
to enclose the oven then please observe the
following clearance and ventilation requirements.
The clearances specied in the diagram are
minimum, increased clearances will aid reliability
and improve the life of the product.
Please give consideration to access for
service in the future, including access to
electrical supply service plug/ isolation
switch. The operator will be charged an
additional fee to cover the cost of gaining
safe access to the oven.
Note:
That the additional fan within the enclosure
should be rated at 500m³/hour.
COUNTER TOP CLEARANCE OF MAJOR HEAT SOURCES
The Merrychef 402s draws in a signicant airow
for cooling purposes. It is essential that the oven is
not located near or is isolated away from any major
heat sources using distances and thermal barriers
as shown in the diagram.
For grills and hotplates allow at least 150mm
clearance either side of the oven.
For a fat fryer allow 300mm inches clearance.
Note that the additional fan within
the enclosure should be rated at
500m³/hour
Ventilation Fan
500m³/hour
Not supplied.
Unobstructed
air ow
into these
areas
Thermal
Barrier
Runs the whole
depth of the oven.
Grill/
Hotplate
Fryer
Please give consideration to access for
service in the future, including access to
electrical supply service plug/ isolation
switch. The operator will be charged an
additional fee to cover the cost of gaining
safe access to the oven.
Thermal
Barrier
Runs the
whole depth
of the oven.
MinimumMinimum