Service manual
Page 27 400 Series Ovens 32Z3769 Issue 1
Control Panel 2: Membrane panel circuit
You will need:
A Digital Multi-meter (D.M.M.)
1. Isolate the oven from the mains supply.
2. Remove the Logic Assembly from the Control
Panel Housing.
3. Unplug the membrane “tail” from the Logic
PCB Assy.
4. Using a D.M.M., check for continuity between
the correct terminals when the pads are
pressed.
5. When the panel has been tested,
re-assemble and re-test the control housing.
525° 350° 400° 440° 480°