9. Position door choke to Door Frame Assembly
making sure it is in the correct orientation (the
top of door choke is marked with âTâ on the
underside).
Stage 1
Stage 2
âTâ
Mark
1 Cavity base S325
2 Choke fingers Top S215
3 Choke fingers Left S215
4 Choke fingers Right S215
11. Tape choke Spacer S325 to the cavity base and
tape choke Spacers S215 to sides and top of
door choke.
Close the door and centralise the door choke.
Fit the remaining 20 M5 washers and nuts
tighten the fixings evenly.
10. Loosely fit 3 off M5 flat washers, 3 off M5
shockproof washers, and 3 off M5 stainless
steel full nuts.
Remove spacing pieces and check door
operation.
PROCEDURE FOR BUILDING AND FITTING MEALSTREAM DOOR
4
2
3
1