Page 5 MC Series Ovens 32Z3329 Issue 4
INSTALLATION INSTRUCTIONS
MC Series Ovens
Power Supply Requirements
The MC–Series oven should be connected to a suitable electricity supply, which can cope with the
switching-on surge that occurs with certain types of catering equipment, such as microwaves.
Because of this requirement, we strongly recommend that a separate, suitably rated supply is
installed for the oven.
The supply for the oven should be fitted with a Type "C" circuit breaker, rated at 16A.
In order to maintain adequate ventilation for air intake and exhaust, and to allow access for
cleaning filters, you must allow a minimum of 50 mm clearance all around the oven. Air intake
temperature should not exceed 35°C - excessive temperature can lead to reduced operating duty
cycle or premature ageing of internal components.
Positioning the Oven
maximum
3 ovens
In a stack
ALWAYS Place containers in the cavity carefully - impact damage may chip the oven shelf
NEVER Install an oven above fryers, grills, griddles or any other major heat source
NEVER Stack machines on top of each other without using the stacking adapter provided.
Stacking Adapter