Service manual
Page 7
MANUAL CONTROLS
below 100ºC
100C-125ºC
above 125ºC
1 POWER PADS
2 CONVECTION PAD
3 TIME/PROGRAM SELECT PADS
4 TEMPERATURE SETTING PADS
5 CANCEL PAD
6 PROGRAM PAD
7 TIME AND PROGRAM DISPLAY
8 MULTI-STAGE INDICATOR
9 COLON
10 ON/OFF SWITCH
11 ERROR DISPLAY
7 TIME AND
PROGRAM
DISPLAY
1. POWER PADS
There are 4 Microwave Power Pads to select from:
25%, 50%, 75%, and 100%. A light will indicate the
one in use.
2. CONVECTION PAD
This is used when foods only require browning( no
microwave)
Note: when cooking the MICROWAVE and
CONVECTION pads start the cycle and timer. You
may alter power levels during a manual cooking cycle.
When cooking is interrupted, a light will flash as a
reminder that the time is being held (see PAUSE).
3. TIME/PROGRAM SELECT PADS
These pads are used for setting the cooking time in 1
second steps to a maximum of 30 minutes.
They are also used for programs from 21-99.
4. TEMPERATURE SETTING PADS
These pads are used to set the convection
temperature. A light will indicate the temperature set.
Selecting the ‘
0
’ key will switch convection off. If a
temperature key is pressed and held the current oven
temperature will be displayed in the time display
window.
5. CANCEL/ CALLBACK ‘C’ PAD
Cancels all timed cooking cycles, pre-programmed
operations and stop the microwave energy. It does not
alter the oven temperature . If the oven is hot food will
continue to cook and should be removed from the oven
immediately. This pad will also cancel any incorrect
operations. It will not erase programs. It can also be
used to view the details of stored programs.
(see CALL BACK)
6. PROGRAM ‘P’ PAD
Activate or set program
7. TIME AND PROGRAM DISPLAY
Shows the time set in minutes and seconds and counts down
in 1 second steps during a cooking cycle.
Also displays error messages and oven temperature.
(PROBLEM SOLVING section 8)
The program display indicates the program number
selected. ‘PP’ indicates programming
8. MULTI-STAGE INDICATOR
Indicates stage in multi-stage cooking
9. COLON
When programming the colon will flash to indicate the
time may now be entered.
10. ON/OFF SWITCH
11. ERROR DISPLAY See PROBLEM SOLVING Section 8.
12. QUICK ACCESS PADS
For programs 01-20
13. START
Starts a quick access program
14. STOP
Stops a quick access program