Power Supply Requirements
The Evolution
should be connected to a suitable electricity supply, which can cope with the
switching-on surge that occurs with certain types of catering equipment, such as microwaves.
Because of this requirement, we strongly recommend that a separate, suitably rated supply is
installed for the oven.
The supply for the oven should be fitted with a
Type "C"
circuit breaker. Please refer to rating
plate for details.
If the oven is hard wired to the supply a double-pole isolator switch with a contact gap of at least
3mm should be fitted.
Positioning the Oven
In order to maintain adequate ventilation for air intake and exhaust, and to allow access for
cleaning filters, you must allow a minimum of 100 mm clearance at the sides and 100 at the rear
of the oven, and at least 100 mm above. Air intake temperature should not exceed 35°C -
excessive temperature can lead to reduced operating duty cycle or premature ageing of internal
components.
NEVER
Install an oven above fryers, grills, griddles or any other major heat source.
NEVER
Stack machines on top of each other - always use a double stand.