eikon e2 Service & Parts Manual NOTE: PLEASE READ COMPLETELY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS EQUIPMENT CAUTION MICROWAVE EMISSIONS: DO NOT BECOME EXPOSED TO EMISSIONS FROM THE MICROWAVE GENERATOR OR PARTS CONDUCTING MICROWAVE ENERGY. Merrychef USA, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Technical Support Hotline: (800) 678-9511 Telephone: (260) 459-8200 www.merrychefusa.
TABLE OF CONTENTS SYMBOLS .................................................................................................................................................................. 4 SAFETY REQUIREMENTS ....................................................................................................................................... 5 PRODUCT OVERVIEW & FUNCTIONS .................................................................................................................... 6 MAIN FEATURES .
MICROWAVE LEAKAGE TEST ................................................................................................................................... 31 TEMPERATURE CONTROL TEST ............................................................................................................................... 32 RECOMMISSION TEST ............................................................................................................................................. 33 HIGH VOLTAGE COMPONENTS ...........
SYMBOLS The symbols below are used, where applicable, as visual guidance throughout this manual DANGER This symbol is shown if there is a high risk of severe personal physical injury. The relevant safety precautions MUST be observed and implemented at all times. WARNING This symbol is shown if there is a possible risk of personal physical injury or if damage may occur to the equipment. The relevant safety precautions MUST be observed and implemented at all times.
SAFETY REQUIREMENTS Important: This manual provides technical guidance for engineers who have successfully undertaken a recognized product familiarization and training course run by Merrychef to carry out service/repair tasks to the appliance/s shown on the front cover of this manual which must not be used for any other make or model of appliance. Please remember that it is wiser not to attempt a service task if you are unsure of being able to complete it competently, quickly, and above all safely.
PRODUCT OVERVIEW & FUNCTIONS CONSTRUCTION • Stainless Steel cavity and casework. CONTROL SYSTEM • Color touchscreen, icon driven. • Storage for up to 1024 programs with 6 stages per cooking program providing a user instruction for each stage. • USB memory stick data transfer. • Support for optional remote communications Ethernet module. • Safety system: ensures control area temperature is within limits. Catalytic Converter Heating Element MICROWAVE POWER • Microwave magnetron.
MAIN FEATURES 1 ON/OFF SWITCH ON (I) activates the oven, OFF (0) switches the oven to standby mode. IT DOES NOT ISOLATE INTERNAL WIRING FROM THE MAINS SUPPLY. 2 CONTROL PANEL Touch sensitive controls (easyToUCH) for controlling oven functions, including diagnostics and service mode. 3 USB menuKey A socket, located under the logo, allows a USB menuKey to be used to update the cooking programs and oven firmware on the control board.
TECHNICAL SPECIFICATIONS Specifications Eikon e2T (Twin) Eikon e2 Overall Size Overall Size 27" 686 mm Height (on 4” legs) Width 14.75” 375 mm Width 31.5” 800mm Depth (overall without handle) 28.5” 724 mm Depth (overall without handle) 28.5” 724 mm Depth (door open 90 degrees) 40.25” 1022 mm Depth (door open 90 degrees) Height (on 4” legs) 27" 686 mm 40.25” 1022 mm 150 lbs. (each) 68 kg (each) 150 lbs. 68 kg Weight Height 9.6” 244 mm Height 9.6” 244 mm Width 9.
OVEN PLACEMENT/INSTALLATION NOTE: Upon receipt of this unit, immediately unpack and inspect for possible concealed shipping damage. If unit is found to be damaged, save all packing materials and contact your delivery carrier immediately. Failure to follow these instructions will negate Merrychef USA’s or your ability to file claims and receive compensation for shipping damage. IF THERE IS APPARENT DAMAGE: United States and Canada: Arrangements should be made to file a claim against the carrier.
ELECTRICAL INSTALLATION DANGER! THIS APPLIANCE MUST BE EARTHED. FAILURE TO DO SO MAY RESULT IN ELECTRIC SHOCK AND DEATH. FOR ALL CORD CONNECTED APPLIANCES: GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug.
QUICK START GUIDE: QUICK SERVICE OVEN The easyToUCH screen display, layout and icons shown herein, are for guidance purposes only and are not intended to be an exact representation of those supplied with the oven. 1 2 3 4 START UP 1. Switch the oven on; Make all the relevant safety checks and ensure the oven is clean and empty before pressing the oven switch down to activate the oven. 2. The easyToUCH screen illuminates with the display briefly showing the serial number and oven data.
USING A COOKING PROGRAM WARNING: Taking all the necessary precautions to ensure you do not burn yourself, open the oven door to place the food into the hot oven and close the door. 1. Select a program group, for example, ‘BURGERS’ to display the individual cooking programs. 2. Select a cook program to start, for example, 2 BURGERS. 3. Follow instructions if displayed on the screen and touch the green ‘check mark’ to cook. 4. The cooking time counts down for each program stage. 5.
OPERATING GUIDE: FULL SERVICE OVEN easyToUCH MAIN MENU & KEYBOARD SCREEN 1. DEVELOPMENT MODE enables multistage cooking programs to be developed, then store under a name and symbol for reuse. 2. PRESS & GO allows quick access to use the cooking programs that are already stored. 1 DEVELOPMENT MODE 3. COOKBOOK contains the oven’s cooking programs. It displays Favorites, Cooking Program Groups and a complete listing of all cooking programs available.
DEVELOPMENT MODE: CREATING A COOK PROGRAM 1 1. Select the ‘chef’s hat’ symbol from the main menu to enter development mode. Enter stage 1 of the program 2. The temperature displays the set preheated oven temperature. To increase or decrease the temperature required, select the temperature symbol (2), enter the temperature in the keypad within the limits displayed and select OK. 3. Select and set the cooking time up to a maximum of 10 minutes. For example: Enter 110 (1minute and 10 seconds). 4.
PRESS & GO Running a cooking program from the Press & Go menu: 1. Select ‘PRESS & GO’ from the main menu screen. 2. Select the item required to cook. 3. The display shows the temperature, cooking time, fan speed and microwave power while the timer counts down. The timer bar turns red to indicate the cooking cycle has finished. 1 2 Choosing which cooking programs are shown 1 in the ‘PRESS & GO’ menu screen. 1. After selecting ‘PRESS & GO’ from the main menu screen, select the EDIT symbol. 2.
USING A COOKBOOK PROGRAM (CONT’D) 4. Select the required cooking program to start cooking. For example, ‘1 BURGER’. 5. The program either starts immediately displaying a countdown timer, or an instruction is displayed first; follow the stage instruction then select OK to start cooking. If the oven door is not opened within 30 seconds a warning message appears. 6.
ADDING A NEW PROGRAM GROUP To add a new Program Group: 1. Select ‘COOKBOOK’ from the main menu screen. 2. Select ‘EDIT COOKBOOK’. 3. Select the ‘ADD A NEW GROUP’ symbol. 4. Enter a name for the new Program Group (max. 20 characters). 5. Select an image to represent the Group. (Use the scroll arrows for more pictures.) 6. Select OK to save the Program Group to the Cookbook. 1 2 4 5 1 2 3 6 Select backspace to return to the ‘COOKBOOK’.
ADDING A PROGRAM TO A GROUP 1 2 3 To add a cooking program to an existing PROGRAM GROUP. Example add Program ‘4 BURGERS’ to the program group ‘BURGERS’. 1. Select ‘COOKBOOK’ from the main menu screen. 2. Select the ‘BURGERS’ Program Group. 3. Select ‘EDIT COOKBOOK’. 4. In the lower part of the screen use the up/down scroll arrows on the right side to find and select the ‘4 BURGERS’ cooking program. 5.
OVEN CONTROL SETTINGS 1. Select the ‘settings’ symbol from the main menu screen. 2. Enter the password and select OK to display the Settings menu (3) comprising: A. Oven mode/navigation settings. B. Language options. C. Oven temperature settings and labels. D. Service information and error logs (password required). E. Recipe counters. F. Date & time settings. G. Speaker sound levels. H. Oven Timer (Temperature/ON/OFF). J. USB program connection. K. Restore settings to Factory defaults. L. Temperature Band.
Recipe counters (E) E 1. Select the clipboard symbol to display a listing of recipe counters. 2. If shown, use the arrows (bottom right) to scroll up and down the list. Date and Time settings (F) 1. Select the time/date symbol to display the setting options. 2. CHANGE THE DATE: Select ‘MONTH’, enter the correct Month on the keypad and select OK. 3. Select ‘DAY’, enter the correct Day on the keypad and select OK. 4. Select ‘YEAR’, enter the correct last two digits of the Year on the keypad and select OK.
USB oven programs (J) J IMPORTANT: Downloading from a USB will clear all the existing programs. Check that the key has the correct number/code for the programs you want to load into the oven memory. 1. Select USB from the settings screen. 2. Slide the USB cover (logo on the oven front) upwards to insert the USB into the slot. 3. When the inserted USB stick has finished flashing select the required USB symbol, for example; RECIPES. 4.
COOLING THE OVEN DOWN BEFORE CLEANING Oven cool down IMPORTANT: the oven must be cooled down before the cleaning processes are carried out. 1. In Full Serve mode, select the CLEANING symbol from the main menu. 2. In Full or Quick Serve mode, select the blue thermometer symbol to disable heating and start the cooling cycle. 3. Taking all necessary precautions place a suitable heaped container of ice, into the hot oven cavity. Select the OK symbol to continue. 4.
Cold Oven CLEANING INSTRUCTIONS e2 Complete COOL DOWN procedure and allow oven and accessories to cool before commencing cleaning. Grease Filters REMOVE & CLEAN Oven Parts: WARNING: DO NOT USE TOOLS 1. Remove the air filter from the back of the oven. 2. Open the oven door, remove the cook plate, bottom jet plate, and grease filters. Wash all parts in warm soapy water. Wash off using a clean cloth and plenty of clean, warm water. Dry by using a fresh, clean cloth.
SERVICING THE OVEN DANGER: Servicing Procedure: BEFORE REMOVING THE OVEN CASING, ISOLATE THE OVEN FROM THE MAINS ELECTRICITY POWER SUPPLY; SWITCH OFF, DISCONNECT OVEN PLUG FROM WALL SOCKET, TURN OFF ISOLATOR SWITCH TO DISCONNECT FIXED WIRED OVENS AND LOCK-OFF. 1. Disconnect/isolate the oven from the power supply. 2. Check the oven is correctly installed as described in the Installation Instructions (Product Details section). 3.
ERROR & DIAGNOSTICS ERROR MESSAGES A 1. A description of the type of error is shown. Check for a number following ‘Error:’ (A) and refer to the Error Codes (Fault Finding Section) for more details. The Oven Serial Number, Model, UI (QTS) version and SRB version information is also displayed below. 2. Clear the Error message by power cycling the mains power supply to the oven (not the oven ON/OFF switch) COPYING ERROR MESSAGES: B 1. Enter oven settings menu (B) and select the USB symbol. 2.
VISUAL VIEW E Select VISUAL VIEW (E) to check the main oven components. Select a component symbol to switch on (red), select again to increase the level or turn off (green). (Screen shots are for illustration purposes only and may not represent true image found on the oven) 1. Open the oven door and check the color changes from green to red on the display to check the door microswitch/interlock circuit is operating.
FIRMWARE UPDATES Note: if icons are not displayed on the screen, press in the same positions on screen as the missing icons to select. 1. Tap the top right of the screen (1) or the same position if it is not displayed to bypass oven preheat. 2. Enter a password (i.e. “Manager”) and select OK (2) or the same position if the green tick symbol is not displayed. 3. Select the USB symbol (3) or the same position if it is not displayed. 4.
IMPORTANT: Downloading from a USB will clear all existing programs. Update the ‘SRB’ first, the ‘QTS’ second and the ‘Icons’ third (found under the USB ‘Recipe’ heading). 7. Switch on the oven and tap the top right of the screen (1) to bypass the preheat stage. 8. Enter the password and select OK to display the Settings menu, see (2). 9. Select the USB symbol (4). 10. Slide the Merrychef badge (oven front top right) upwards and insert the USB Memory Stick into the slot (3).
OVEN TESTING Equipment required: • • Digital Multi-meter (D.M.M.). Microwave detection / leakage meter. DANGER: BEFORE REMOVING THE OVEN CASING, ISOLATE THE OVEN FROM THE MAINS ELECTRICITY POWER SUPPLY; SWITCH OFF, DISCONNECT OVEN PLUG FROM WALL SOCKET, TURN OFF ISOLATOR SWITCH TO DISCONNECT FIXED WIRED OVENS AND LOCK-OFF.
OVEN TESTS 1. Enter Service mode (Servicing section). 2. Select the down arrow to display the individual Oven tests (A) for the oven to perform. A Microwave Power Test Measuring the power output Note: The power output is established under IEC 705 standard method which is only workable in laboratory controlled conditions. Power output is also affected by line voltage under load, so this test is an approximation only. 1. [4Ensure the oven is cold, then enter Service mode to bypass oven preheating. 2.
Microwave Leakage Test Note before measuring: • Make sure that the survey meter you are using has been calibrated and is suitable for measuring frequencies of 2,450 MHz. • Do not exceed meter full scale deflection, leakage meter should initially be set to the highest scale, then adjusted down as necessary to ensure that low readings are measured on the most sensitive range. • To prevent false readings, hold the probe on the grip provided and move at 2.5cm/second.
Temperature Control Test Measuring the oven cavity temperature (Note; re-calibrating the Thermocouple with the SRB is normally only required when the Thermocouple has been replaced or the oven is under or over cooking.) Procedure: 1 Place the probe of a temperature reader (A) onto a heat sink in the centre of the oven cavity and close the oven door. 2 Select ‘Temperature Control Test’ (B) from the service mode tests. The oven heats up and cycles at the maximum set point temperature over 30 minutes.
Recommission Test The Recommission tests are performed following the completion of a service or repair to ensure the oven is operational before handing back to the customer. Some of the tests have a countdown timer where failing to carry out a test within the time limit will cause a test failure and the Recommission test will have to be restarted. A RECOMMISSION TEST Procedure: 1 Select ‘Recommission Test’ (A) from the service mode oven tests and follow the on screen instructions to perform the tests.
HIGH VOLTAGE COMPONENTS High voltages and large currents are present at the High Voltage Capacitor. It is very dangerous to work near this part when the oven is on. NEVER make any voltage measurements at the High Voltage circuits, including the magnetron filament when connected to mains power supply.
High voltages and large currents are present at the High Voltage Capacitor. It is very dangerous to work near this part when the oven is on. NEVER make any voltage measurements at the High Voltage circuits, including the magnetron filament when connected to mains power supply. Even when the oven is not cooking, the High Voltage Capacitor has High Voltages present because of the Soft Start circuit. a High Voltage Capacitor Test 1 2 3 4 5 6 Disconnect and isolate the oven from the electricity supply.
MAINS VOLTAGE COMPONENTS 4 Door Interlock Adjustment Located on the door hinges are 3 safety interlock microswitches, to prevent microwave emissions escaping when the oven door is opened: The Primary (SW3) breaks the electrical supply circuit to the transformers. The Secondary (SW2) breaks the microwave circuit if the primary fails. 3 1 3 The Monitor switch (SW1) will short out the Microwave circuit blowing the fuse if both Primary and Secondary interlocks fail.
Convection Fan Motor & Controller Convection Fan Motor The convection motor is a 3-phase AC motor having a maximum speed of 3600 rpm controlled by a motor speed controller. The windings are thermally protected and in the event of a thermal fault a trip inside the motor will operate and shut down the motor speed controller. Motor Controller Provides a 3-phase AC switched mode drive to the convection motor and is controlled by a 0 - 10 Volt signal from the SRB.
OVEN COMPONENTS 1 DANGER: 2 3 BEFORE REMOVING THE OVEN CASING, ISOLATE THE OVEN FROM THE MAINS ELECTRICITY POWER SUPPLY; SWITCH OFF, DISCONNECT OVEN PLUG FROM WALL SOCKET, TURN OFF ISOLATOR SWITCH TO DISCONNECT FIXED WIRED OVENS AND LOCK-OFF. WARNING: ALLOW OVEN TO COOL AND OBSERVE AND FOLLOW ALL SAFETY PRECAUTIONS INCLUDING THOSE DESCRIBED UNDER THE SAFETY REGULATIONS SECTION OF THIS MANUAL BEFORE ATTEMPTING A SERVICE OR REPAIR.
3 Back Side (Outside) Components 1 Main Fan Motor 2 Cooling Fans 3 Magnetron Fan 4 Power Cord Top Side Components 5 QTS Touch Screen 6 SRB Smart Relay Board 7 Power Switch 8 Step-down Transformer 24V 9 Oven Cavity High Limit 10 Stirrer Motor 11 HV Capacitor 12 Waveguide 13 HV Magnetron 14 Magnetron High Limit 15 RFI Filter 16 Motor Controller 17 HV Diode Board 18 HV Transformer 19 Voltage Select Relay 15 13 1 4 17 16 14 E2 SERVICE MANUAL REV D 09/12 2 12 18 11 6 19 9 10 5 8 7 39
SRB & QTS CIRCUIT BOARDS SRB replacement 1 Disconnect and isolate the oven from the electricity supply. 2 Allow the oven to cool down. 3 Remove the oven casing. 4 Ensure that the High Voltage Capacitor is discharged before commencing work. 5 Taking anti-static precautions disconnect all connections on the SRB. 6 Remove the PM (Personality Module) (1) from the SRB and place safely aside. 7 Release retaining screws and remove the SRB (2). 8 Replace SRB and secure retaining screws.
(Personality Module) Replacement 1 The PM on the SRB contains the Firmware. The PM on the QTS contains the Firmware, Oven Serial Number, Temperature Calibration, Cooking Programs, Application Icons and the Recipe Images. 1 With a new PM fitted and casing refitted, switch on the oven and tap the screen to hold and check the QTS and SRB versions (1) are the latest release, if not, execute a Firmware update using the latest versions. For details see ‘Firmware Updates’ (Servicing section).
SPARE PARTS EXPLODED VIEW 47 18 39 2 1 45 44 17 4 33 43 46 68 26 63 41 20 10 3 24 14 40 42 32 48 34 19 7 9 8 11 28 6 62 29 70 54 69 59 25 22 71 77 37 16 27 55 74 13 REPLACEMENT SPARES & 75 21 76 38 52 73 23 50 72 57 51 56 15 30 58 12 42 E2 SERVICE MANUAL REV D 09/12
SPARE PARTS Parts list Item # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 E2 SERVICE MANUAL REV D 09/12 Spare Part # 333000 333001 333002 333003 333004 333005 333006 333007 333008 333011 333015 333016 333019 333261 333023 333024 333033 333034 333036 333078 333268 333269 333082 333083 333084 333085 333087 333089 333013 333091 333094 333098 333109 333110 333115 333121 333270 333271 333167 333173 333174 333175 Description Magnetron Hig
Item # 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 44 Spare Part # 333176 333177 333178 333179 333180 333182 333183 333184 333185 333186 333187 333188 333189 333190 333191 333192 333193 333194 333195 333196 333197 333198 333199 333200 333201 369125 333205 333206 333207 333208 333209 333210 333211 333212 333021 Description Relay 12v Mag Fan Shroud 2 Mag Fan Shroud Diode Board Bracket Wave Guide Stirrer Antenna Motor Mount Assembly Door Gasket Do
ERROR CODES DISPLAYED Error Code E000 E083 Error/Event Condition Oven All E2, E6 E2, E6 OK Incompatible SRB software version Invalid Date Description E086 E087 E088 None E2, E6 E6 All E2 SERVICE MANUAL REV D 09/12 Recommission fail Elevator Error Level Communication between the QTS and the SRB has been reestablished. The SRB was previously in a communication N/A error state (E107) and the error has now cleared.
Error Code Oven E3, E4, E5 Error/Event Condition Recommission fail Cooling fan(s) E089 E2, E6 E090 All Recommission fail Convection fan E091 E3 Recommission fail – Turn Table E2, E3, E4, E5 Recommission fail – Convection Heater E6 Recommission fail – High Convection Heater Description Trigger At oven start up the QTS senses that the AC mains voltage read from the SRB is out of the ±10% The cooling fan(s) Pressing the "Red failed the X" when recommission test "CONFIRM N/A COOLING FAN IS RU
Error Code Oven Error/Event Condition E094 E3, E4, E5 Recommission fail Filter in E095 E3, E4, E5 Recommission fail Filter out E096 All Recommission fail Door close E097 All Recommission fail Door open E098 All Incomplete Cleaning E099 E3, E4, E5 Filter Override E100 E101 All All E2 SERVICE MANUAL REV D 09/12 Main power ON Magnetron failed Description Trigger Error Level System Response The oven does The SRB does not not sense that the see the magnetic filter is installed swi
Error Code Oven E2, E3, E4, E5 Error/Event Condition Heater On Description Trigger Error Level Convection Heater element failed to turn OFF when requested The current measured by the SRB is >1 amp Critical with the convection heater OFF High Convection Heater element failed to turn OFF when requested The current measured by the SRB is >1 amp with the high heater OFF The temperature measured inside the ovens cabinet is too high The ambient temperature measured by the Warning QTS and or SRB is >7
Error Code E108 E109 Oven All All All Error/Event Condition QTS PM error SRB PM error Incompatible SRB software version Description Trigger Wrong QTS PM found / no QTS PM found The QTS has an incorrect PM (personality module) installed or no PM is installed Wrong SRB PM The SRB has an found / no SRB incorrect PM PM found (personality module) installed or no PM is installed SRB firmware The SRB has version is found that the incompatible with firmware running the SRB the SRB is not supported.
Error Code Oven Error/Event Condition Description N/A E114 None Spare (not used) Trigger Error Level N/A N/A The convection fan has failed E115 E6 E2, E3, E4, E5 The feedback from the convection fan controller has Convection Fan failed Critical indicated to the SRB that the controller has Convection heater The SRB senses element failed to that the heater turn On current is <1 amp Critical Heater off when requested to be ON E116 E6 High Heater off E3, E4, E5 Magnetron overheat E2, E3 Mag
Error Code Oven Error/Event Condition E6 Right Magnetron overheat E118 N/A Bottom Convection Fan failed E119 E6 Low Heater On E120 E6 Low Heater Off E2 Radiant On Description Trigger Error Level The right The right magnetron magnetron thermal thermal switch cut-out has Warning has released but released while the the condition right magnetron is clears in time running and the The right The right magnetron magnetron thermal thermal switch cut-out has Critical has released but released while
Error Code Oven E2 Error/Event Condition Radiant Off Description Trigger Radiant heater Not Implemented element failed to Yet turn On Error Level Critical E122 E6 E123 None E6 E124 E125 E126 E127 52 None None E2, E6 Elevator failed The current measured by the SRB is lower than what is expected. The calculation is affected by the The food elevator The system has failed. determined that the food elevator is Critical not operating correctly.
SRB & QTS CIRCUIT BOARDS QTS LEDs • Run - Pulsing 1 second flash, indicating that the board has booted up. • Power - Lit to show that there is a power supply from the SRB. • P-Bus - Irregular flashing, indicating data communication with SRB. • C-Bus - Lit to show data being loaded from the PM onto the QTS. • LD5 - Lit to show. 1 LD5 2 Power, Run, P-Bus, C-Bus.
SRB LED’s • P-Bus - Irregular flashing, indicating data communication with QTS. • Run - Pulsing 1 second flash, indicating that the board has booted up. • 12v & 5v - Lit to show voltage outputs from inboard transformer. • Relay & Triac - Lit to show that a signal has been sent to energize that component. 1 Cooling fan. 2 Convection fan. 3 Stirrer. 4 5v supply. 5 12v supply. 6 Heater safety. 7 Heater drive. 8 P-BUS: flashes when data is being sent / received. RUN: 1 second flash. 9 Oven Door.
SRB Terminal Locations: 1 X3 - Output for e2 Convection Fan Controller. 2 X101 - Voltage Selection Relay coil feeds. 3 X18b – Air Intake Filter Reed (Jumper) 4 X18e – Right Magnetron Thermostat (Jumper) 5 X18d - Magnetron Thermostat (Top).
CIRCUIT DIAGRAMS 56 E2 SERVICE MANUAL REV D 09/12
E2 SERVICE MANUAL REV D 09/12 57
E2 SERVICE MANUAL REV D 09/12
E2 SERVICE MANUAL REV D 09/12 59
E2 SERVICE MANUAL REV D 09/12
COMMISSIONING THE OVEN Initial Installation After Service 1. Unpack the Oven and check for damage. 2. Check Oven Accessories. 3. Check location will provide adequate Ventilation. 4. Locate Oven onto a strong, level, non-flammable Surface. 5. Remove panels & check all wiring and components for security. 6. Refit panels. 7. Position the Oven with a minimum air gap of 2” (50mm) sides & rear. 8. Check Electrical supply and connect. 9. Place a container of water in the oven and switch it on. 10.
LIMITED WARRANTY FOR COMMERCIAL PRODUCTS LIMITED WARRANTY Merrychef USA, (“Merrychef”) warrants this product to be free from defects in material and workmanship for a period of one (1) year from the date the product is installed or eighteen months (18) months from the date of shipment from our facility, whichever comes first.
Notes: E2 SERVICE MANUAL REV D 09/12 63
Merrychef USA, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Technical Support Hotline: (800) 678-9511 Telephone: (260) 459-8200 www.merrychefusa.