Specifications
Service & Parts Manual original Instructions
Part Number 32Z3809 GB
Issue 1
47
FAULT FINDING
Error
Code
Error Condition Description Trigger Possible Causes
Error
Level
System
Response
E 111
Cavity sensor
error
Cavity sensor broken
/ unplugged
The controller is
reading an open
circuit across the
thermocouple
input
The
thermocouple
is not
connected. The
thermocouple
is broken open
circuit. Failed SRB.
Critical
Display error
message until
system is
power cycled.
N/A
Oven door open
longer than 1 min.
Oven door open.
Oven inoperable.
Break in
switched feed
on SRB
Door left open.
Failed door
switch/s or SRB.
Faulty wiring or
connection.
Warning
Display
warning
message until
door is closed.
N/A Air Filter removed
Air lter not tted.
Oven inoperable.
Filter not tted.
Failed reed
switch/s or SRB.
Faulty wiring or
connection.
Warning
Display error
message until
lter replaced.