Specifications
10
Service & Parts Manual original Instructions
Part Number 32Z3839 GB
Issue 5
Service & Parts Manual original Instructions
Part Number 32Z3839 GB
Issue 5
11
PRODUCT
DETAILS
PRODUCT
DETAILS
1
Earth
Brown
Blue
SINGLE PHASE OVEN LOADING
Earth connection is essential.
Phase Loading Diagram
BLUE
Rear view of plug
Plug Type:
Single Phase
32Amp
IEC 60309
[EN60309]
L1+N+E
32 Amp Plug
BLACK
Rear view of plug
plug type:
Single Phase
13Amp
IEC 60309
[EN60309]
L1+N+E
13 Amp Plug
BLACK
Rear view of plug
plug type:EU1-16P
Single Phase
16Amp
IEC 60309
[EN60309]
L1+N
16 Amp Plug
Yellow/Green
DANGER!
THIS APPLIANCE MUST BE EARTHED. FAILURE
TO DO SO MAY RESULT IN ELECTRIC SHOCK
AND DEATH.
The oven must be connected to a separate
electrical supply installed by a qualied and
approved electrician.
A suitably rated isolating switch with a 3mm
contact gap on all poles should be tted for each
oven installed.
WARNING
HIGH LEAKAGE CURRENT.
EQUIPOTENTIAL
An Equipotential Earth point is provided on
the rear panel of the oven for independent
Earth (GND) connection.
7 ELECTRICAL INSTALLATION
Establishments with standard (Type ‘B’) circuit
breakers are sensitive to ‘surges’ which occur on
switching on freezers, refrigerators and other
catering equipment, including microwave ovens.
Because of this, we strongly recommend that
a separate Type ‘C’ circuit breaker (designed
specically for this type of equipment) must be
tted. An individual, suitably rated circuit breaker
should be tted for each oven installed.
DANGER!
THIS APPLIANCE MUST BE EARTHED.
FAILURE TO DO SO MAY RESULT IN
ELECTRIC SHOCK AND DEATH.
The oven must be connected to a separate
electrical supply installed by a qualied and
approved electrician.
A suitably rated isolating switch with a 3mm
contact gap on all poles should be tted for
each oven installed.
WARNING: HIGH LEAKAGE CURRENT
EARTH CONNECTION IS ESSENTIAL.
If you are in any doubt about your electrical supply, seek the
advice of a qualied electrician.
SINGLE PHASE
BLUE (NEUTRAL)
GREEN & YELLOW (EARTH)
BROWN (LIVE)
This equipment complies with EN61000-3-11 when
connected to a mains supply having a maximum
impedance (Z
MAX
) of 0.1134ohms.
When connecting sensitive equipment to the same
supply as the oven the user should determine in
consultation with the supply authority, if necessary,
that the equipment is connected only to a supply of
Z
MAX
or less.
SINGLE PHASE (1)
UK models are tted with a UK 3 Pin 13 amp Plug to
IEC 60309 (EN 60309)
The Circuit Breaker should be rated at 25A for
20Amp rated ovens (Type C).
The Circuit Breaker should be rated at 20A for
13/16Amp rated ovens (Type C).
EQUIPOTENTIAL
An Equipotential Earth point is
provided on the rear panel of the
oven for independent Earth (GND)
connection.
POWER SUPPLY: EARTH LEAKAGE CIRCUIT
BREAKERS
If the oven is connected to an Earth Leakage Circuit
Breaker device, this should allow a minimum of 30
milliamperes earth current without interrupting the
circuit.
8.1 Phase Loading
Oven loading per phase is not equal therefore we
recommend that other electrical equipment is
connected to L3+ N.
Circuit Breakers
SINGLE PHASE
Circuit Breakers should be rated at 25A per Phase for
20A rated ovens
Circuit Breakers should be rated at 20A per phase for
13/16A rated ovens
and be Time Delay, Motor Start Type (European Type C).
Earth Leakage Circuit:
If the oven is connected to an Earth Leakage Circuit
Breaker device, this should allow a minimum of 30
milliamps earth current without interrupting the circuit.
If you are in any doubt about your electrical supply,
seek the advice of a qualied electrician.