Service manual
Page 5 Mealstream Ovens 32Z3387 Issue 3
Installation Instructions for Mealstream 500 series Combination Ovens
Power Supply Requirements
The Mealstream 500 series oven should be connected to a suitable electricity supply, which
can cope with the switching-on surge that occurs with certain types of catering equipment, such
as microwaves. Because of this requirement, we strongly recommend that a separate, suitably
rated supply is installed for the oven.
The supply for the oven should be fitted with a Type "C" circuit breaker, rated at:
30 Amp for Mealstream 500 Series (all models)
If the oven is hard-wired to the supply, a double-pole isolator switch with a contact gap of at
least 3mm should be fitted and positioned close to the oven to allow the oven to be moved for
servicing.
Positioning the Oven
In order to maintain adequate ventilation for air intake and exhaust, and to allow access for
cleaning filters, you must allow a minimum of 50mm clearance at the sides and rear of the
oven, and at least 50mm above. Air intake temperature should not exceed 35°C - excessive
temperature will lead to reduced operating duty cycle or premature ageing of internal
components.
Failure to comply with these conditions will invalidate the warranty.
NEVER Install an oven above fryers, grills, griddles or any other major heat source.
NEVER Stack machines on top of each other - always use a double stand.
ALWAYS Place containers in the cavity carefully - impact damage may chip the
vitreous enamel coating on the runners and baffle plate.
Installation instructions:
50mm 50mm
50mm
50mm
350mm