Service manual

Page 41
Page 1 of 2
1. Isolate oven from mains power
supply.
2. Remove necessary covers to obtain
access to the L/H inner side panel.
3. Remove the wires from the existing fuse holders and fit them
to the FLM20 fuse holders Pt. No. 30Z1178. (A)
4. Remove fuses and unscrew the existing fuse holders, discard
all parts.
5. Secure the new fuse holders into positions using No.6x1/2” self
tap screw Pt. No. 31Z3116 x2. The fuse holders are to be
locked together prior to fitting into the hole shown in the
diagram. (B)
B
A
A
APPENDIX 7: Fuse change (FLM20) 1
Part No. Description Quantity
30Z1177 20A littlefuse FLM020 2
30Z1178 30A fuse holder (FLM Series) 2
31Z2092 Label - 20A FLM fuse 1
31Z3116 6x1/2” self tap pan 2
Mealstream ovens manufactured before March 2004
Brief description:
13A anti-surge fuses Pt. No. 30Z0168 are no longer manufactured these are now replaced with
FLM020 fuses Pt. No. 30Z1177 for the Microwave circuit on all Mealstream 501 ovens.
To replace a fuse on an oven manufactured before March 2004 and fitted with this fuse type it is
necessary to replace the fuses and fuse holders with FLM 020 type.
Procedure for replacing 13A anti-surge Fuses with FLM020 type