Midyear 2S wireless compact security series Installation and user’s manual Table of contents 1. System introduction 1-1 feature introduction 1-2 list of components 1-3 control unit keypad and LED indicator introduction 2. Midyear 2s usage 2-1 control unit usage 2-2 remote control usage 3, System setup 3-1 alarm status 3-2 modes of reporting to police 3-3 detector setup a. Setup of door/window transmitter b. Setup of PIR motion detector 3-4 replacing battery of detector 4, Installing Midyear 2S.
1. system introduction 1-1 feature introduction * capable of storing and dialing 4 sets of phone or pager number in any combination. ¢ capable of vocally reporting 4 different alarm situations. capable of line-seizure (no special telephone line required) * built-in tamper alarm on detectors. * built-in rechargeable battery in control unit capable of supplying power for 12 hours. * battery-low indicator available on control unit & detector. * 1,048,576 sets of system identification code available.
ZL & Door/Window PIR quotient 3-Key Remote Transmitter Detector Controller Control Unit Alarm Siren 12V DC Adapter 1-3 control unit keypad and LED indicator introduction s. 123 O Disarming O Sen. Battery low tamperer QO Zone O Program : B > Record Fr ere a. Power: the LED is cons, tenthly on when the system power supply is normal. b. Army Disarm: the LED blinks when the control unit is in “away” mode. the LED is consistently on when the unit is i “home” mode.
2. midyear 2s usage 2-1 control unit gauge a. entering program mode; A access to the control unit is guarded by a d-digit user ID (originally by entering this user ID. the control unit will be in program mode, to change the current alarm mode of the control unt. you «iil only be able the program mode by key-in the 4 digit user ID. INPUT FORMAT: user ID + # (the control unit is in program mode as the program LED turns on.
J. setting the system in battery replacement meed: set the control unit in battery emplacement mode before proceeding to do so. INPUT FORMAT: user soon as the input sequence is done, the keypad back light will blink and beep. press any key to exit from this particular mode. k. disarm: when the system is in critical alarm situation, disable the alarm with the following means: (1) using keypad: input user using remote control: press the OFF button, EN 2-2 remote control usage = a.
4-2 installing alarm siren there is one high-pitch alarm siren included in the package. for each critical alarm situation, it generates a high-pitch sound of aver 110 dB 1-attract attention from your neighborhood. a. b. mount the alarm siren at the chosen position, adjust the alarm-siren to the desired angle. connect the line to the socket at hack of the control unit. 4-3 installing door/window transmitter installing PIR motion detector 7 the installation procedure is as follows: oop a.
* 3 this product is designed for indoor use only. THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS : (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.