Operating instructions

21
Your door opener is programmed with self-diagnostic
capabilities. The “Learn” button/diagnostic LED will flash a
number of times then pause signifying it has found a
potential issue. Consult Diagnostic Chart below.
Symptom: One or both of the Indicator lights on the safety reversing sensors
do not glow steady.
Inspect sensor wires for a short (staple in wire), correct wiring polarity (black/white
wires reversed), broken or disconnected wires, replace/attach as needed.
Disconnect all wires from opener.
Remove sensors from brackets and shorten sensor wires to 30-60mm (1-2”) from
back each of sensor.
Reattach sending eye to opener using shortened wires. If sending eye indicator
light glows steadily, attach the receiving eye.
Align sensors, if the indicator lights glow replace the wires for the sensors. If the
sensor indicator lights do not light, replace the safety reversing sensors.
Symptom: LED is not lit on multi-function door control.
Inspect Multi-Function Door Control/wires for a short (staple in wire), replace as
needed.
Disconnect wires at multi-function door control, touch wires together. If opener
activates, replace multi-function door control.
If opener does not activate, disconnect multi-function door control wires from
opener. Momentarily short across red and white terminals with jumper wire. If
opener activates, replace multi-function door control wires.
Symptom: Sending indicator light glows steadily, receiving indicator light is
dim or flashing.
Realign receiving eye sensor, clean lens and secure brackets.
Verify door track is firmly secured to wall and does not move.
Symptom: The RPM Sensor = Short travel 150-200mm (6-8").
Unplug unit to reset. Try to operate opener, check diagnostic code.
If it is still flashing 5 times and opener moves 150-200mm (6-8"), the unit’s APE
(Absolute Positioning Encoder) may need to be replaced, for details contact your
Chamberlain reseller.
Symptom: Door reverses while closing.
Check for possible door obstructions and remove.
Ensure factory installed resistor is installed correctly across the green terminals.
Symptom: Door won’t close
Check for possible door obstructions and remove.
Check beam alignment.
Reversal indicator
Possible RPM sensor
failure. Unplug to reset.
Safety reversing sensors
slightly misaligned
(dim or flashing LED).
Multi-function
door control or
wire shorted.
Safety reversing sensors
wire shorted or black/white
wire reversed.
Safety reversing sensors
wire open (broken or
disconnected).
1 FLASH
2 FLASHES
3 FLASHES
4 FLASHES
5 FLASHES
9 FLASHES
OR
I
nstalled
Safety Reversing
Sensor
Learn
Button LED
or Diagnostic
L
ED
“Learn
B
utton
DIAGNOSTIC CHART
Reversal indicator
10 FLASHES