Service manual

COPYRIGHT © 2005 MERIT INDUSTRIES, INC.
Troubleshooting Information - Mars 2000 Bill Acceptor DIP Switch Settings
Megatouch MAXX Technical Reference Manual
DIP Switch Settings for the Mars 2000 Bill Acceptor
(The DIP switches are located on the side of the bill acceptor)
SETTING SWITCHES
1 WAY DIP 1 ON/DIP 2 OFF
2 WAY DIP 1 OFF/DIP 2 ON
4 WAY DIP 1 ON/DIP 2 ON
HIGH ACCEPTANCE DIP 3 OFF
HIGH SECURITY DIP 3 ON
*$1 DIP 4 ON=ACCEPT/OFF=REJECT
*$2 DIP 5 ON=ACCEPT/OFF=REJECT
*$5 DIP 6 ON=ACCEPT/OFF=REJECT
1 PULSE PER DOLLAR DIP 7 OFF
*4 PULSES PER DOLLAR DIP 7 ON
ALWAYS ENABLE DIP 8 OFF
HARNESS ENABLE DIP 8 ON
* Recommended factory settings allow for acceptance of $1, $2, and $5 bills at 4 pulses per dollar.