Specifications

Tr o u b l e s h o o t i n g
2 7
The DVP-1080 has locked up. How do I reset the processor?
There are three options available to re-boot the processor.
Level ONE
Set the DVP-1080 unit in Stand-By mode; LED indication is RED. Disconnect the power
plug from the processor; reconnect the power plug to the processor and allow the unit to
re-boot.
Level TWO
Enter the SETUP MENU by pressing
Menu on the IR remote for seven seconds
Press
A on the IR remote once
LCD display will indicate SET: RESTORE FACTORY / <PRESS STORE KEY>
Press
Store on the IR remote
Front Panel LCD display will indicate ARE YOU SURE?
Press
Store again to confirm
Note: This action will clear all programmed PROFILES and reset the DVP-1080 to Factory
Defaults.
Level THREE
Connect to the DVP-1080 RS-232 CONTROL port using Windows HyperTerminal program
and a standard Modem Cable).
TYPE dvp,setft
R denotes a carriage return, or pressing R button on the keyboard
Note: This action will clear all programmed PROFILES and reset the DVP-1080 to Factory
Defaults