- Meridian Controlled Routing Installation And Upgrade Guide
538 Chapter 19: Single Terminal Access
553-3202-210 Standard October 1998
8 Configure the MSDL port for STA. Define the port and its
characteristics by responding to the following prompts in LD 17.
Substitute the device number where ÒxÓ appears in the Response
column.
Table 147
LD 17ÑConfigure MSDL port
Prompt Response Comment
REQ CHG Create or change information in the database
TYPE CFN Configuration record data block
ADAN NEW TTY x Add TTY with a logical ID x (0-15). The TTY
number must be the same as the DNUM of
the MSDL.
CTYP MSDL Card type is MSDL (automatic response)
GRP 0 Network Group Number (this prompt appears
only for Option 81 systems)
DNUM x Device number; same as TTY (automatic
response)
PORT 0 Admin port number (automatic response)
DES STA_ADMIN Designate port 0 for the STA terminal.
BPS 9600 Baud rate
PARY NONE Parity type
STOP 1 Number of stop bits
BITL 8 Data bit length
PARM RS-232 DCE Interface and transmission mode
FUNC ABD FCL LME MSDL card functions
USER MTC SCH BUG Output message types
XSM NO SDI port for the system monitor
TTYLOG <cr> Log buffer size
<cr> through remaining prompts