- Meridian Controlled Routing Installation And Upgrade Guide
182 Chapter 9: Meridian Link/CCR interface cabling
553-3202-210 Standard October 1998
5 Connect the ports of octopus cable NT1R03AA to external
equipment as described in Table 60 and shown in Figure 47. For
example, connect port 1 of the NT1R03AA octopus cable to the
console using a customer-supplied cable.
Table 60
Option 11 IPE Module external connections (NT1R03AA cable)
NT1R03AA
port
External equipment External cable or reference
1 console Customer-supplied cable. See
Table 62 for pinout.
3 conshare See ÒSDI and ESDI/MSDL
cabling (Option 11 IPE Module
only).Ó
5 AML See ÒSDI and ESDI/MSDL
cabling (Option 11 IPE Module
only).Ó
7 terminal/printer NT1R03D
Ethernet Ethernet LAN See ÒInstalling Ethernet LAN
support.Ó
6 Connect the ports of cable NT1R03BA to external equipment using
extension cables, as described in Table 61 and shown in Figure 47.
For example, connect port 2 of the NT1R03BA cable to the external
modem using extension cable NT1R03HF.