148 Chapter 8: Hardware installation procedures
553-3202-210 Standard October 1998
Table 40 (Part 1)
Program socket selection
Option Port no. Socket number
DTE (terminal) 1
2
UA10
UA17
UA12
UA19
DCE (modem) 1
2
UA9
UA16
UA11
UA18
RS-232-C interface 1
2
UB9
UB16
UB11
UB18
High-speed interface 1
2
UB10
UB17
UB12
UB19
Set as DCE to emulate modem.
Table 40 (Part 2)
Switch S2ÑAddress selection
Device no. Style A Style B
12341234
0-1 off off off - off off off -
2-3 on off off - off off on -
4-5 off on off - off on off -
6-7 on on off - off on on -
8-9 off off on - on off off -
10-11 on off on - on off on -
12-13 off on on - on on off -
14-15 on on on - on on on -
ON = synchronous mode; OFF = asynchronous mode.
Asynchronous mode is not supported. However, in releases prior to X11 Release 18,
asynchronous mode may work in some applications. With Release 18 and later, asynchronous
mode will not work.