Specifications
maximum and the minimum release values.
Release (55)
Unit: ms - Value Range: 1.45ms / 10884.35 ms
Default Value: 544.22 ms
Sets the manual release value and the maximum release value when in Advanced Mode.
Release Minimum (56)
Unit: ms - Value Range: 1.45ms / 5456.99 - Step: 0.01
Default Value: 1.45 ms
Sets the minimum release value when in Advanced Mode.
Dynamic Profile (57)
Default Value: Solera
Flux processors offer many different manners to detect the dynamic of the signal that is involved in the Auto and Advanced
modes for release.The Angel'Share and Hysteresis actions also rely on the detected dynamic.
•
Solera
> almost universal, great for vocals
•
Beat 1
> hi pitched rhythm material
•
Beat 2
> low pitched rhythm material, great for bass and bass drum
•
Beat 3
> high dynamic range rhythm material, great for drums tracks
•
Beat Average
> rhythm material
•
Max
> very versatile and reactive
•
Average
> less sensitive to dynamic variations
Depending of the audio signal the differences can be subtle or obvious. There's no rule. Spending time experimenting these
Dynamic Profiles allows to benefit of all the sophistication of the Flux algorithms.
Dynamic Velocity (58)
Unit: % - Value Range: 10 / 1000 - Step: 1
Default Value: 50 %
Sets the speed of variation between Release Minimum and release Maximum when in Advanced Mode for release.
Band Display
Input Level Meter (28)
Vu-meter not peak-meter, referenced to -16 dB Fs by default, with auto scale depending of the threshold values.
When the MS Width section is engaged, the M (Mid) level is displayed on the left meter. S (Side) is displayed on the right
meter.
The green index reflects the threshold value.
Output Level Meter (29)
4.2 Alchemist The Parameters