Horus Release Notes Horus Release Notes www.merging.
Horus Release Notes HORUS FIRMWARE Make sure that you are running the latest certified firmware: http://www.merging.com/horus/download Verify your Horus firmware version by going to the Horus Setup menu and open the System info page to verify the firmware version installed. Refer to the Horus User Manual Firmware Update section in order to proceed with a Firmware update. Note: There are two types of Horus updates possible.
Horus Release Notes Improvement: Horus RAVENNA support for different latency modes (samples) Ultra Low (16 smp) Extra low (32 smp) (48smp) for AES67 support Low (64 smp) Fixed. AD module small clicks in gain adjustment when Low Cut is enabled Fixed. Timestamp of the first sample of a frame was not correct causing a problem with the RAVENNA ASIO Driver Fixed. Horus MTC stream was not correct on minute changes, causing Third Party DAW (e.g.
Horus Release Notes Improvement: Horus Error report (on Horus TFT) Improvement: Pull Up / Pull Down support when locked to video reference Improvement: AD module Mic alignment selector Improvement: Horus Monitor module: Stereo channels routing selector (1-2/3-4/5-6/7-8) Improvement: Fan, cooling mode set to low at start up only (to avoid noise) Improvement: WebApp: At the browser opening we automatically open the latest page chosen by the user Fixed.
Horus Release Notes Fixed in Firmware version 18725: Warning: Users updating from a firmware < 18491 (RC1) will need to perform a second Shutdown of the Horus after the Firmware update (in order to initialize correctly the AD and DA modules) Improvement: Metering support on the Web Access Page (see Horus user manual for details) Improvement: The Horus TFT Meter page will gray out all inactive MADI leds Improvement: WordClock output now supported at all sampling rates Improvement: Lock mechanism imp
Horus Release Notes Fixed. Larger Wordclock range of deviation allowing some highly deviating clock sources (more than 100 ppm) to lock correctly Fixed. RAVENNA small mute on random streams Fixed. Some Horus were always rebooting in Maintenance Mode or hanging on “starting application” screen Fixed. Limit preamp fader moves to the group min and max for all members of the group Fixed. Horus being muted at times (needing extra reboot).
Horus Release Notes Fixed: WordClock support with phase alignment Fixed: The D/A Small fade in apply on source is now removed Fixed: TFT splashscreen option (Setup>Advanced) Fixed: Web Control access: PreAmps Metering range for Mics and Line Fixed: Web Control access: PreAmps Mic Pading range indication Fixed: Web Control access: PreAmps Mic/Line Coherency and relative group Gains support Fixed: Web Control access: Horus User Manual embedded (now working with Chrome) Fixed in Firmware versi
Horus Release Notes HORUS TROUBLESHOOTING Rollback Firmware Users that need to rollback to a previous firmware version can do so, but will have to make sure that their Maintenance Mode version is also being rollback if doing so. Firmware v427 and above go with Maintenance Mode v23 Firmware v323 and below go with Maintenance Mode v10 Note: What might occur if your Firmware version is not in front of the Maintenance Mode version is that the Horus might always start up in Maintenance mode.