User manual
www.merging.com/horus Page 35 - 54
Horus User Manual
Modules Menu (Setup)
Module menu will show the available Horus Module that your Horus has in its configuration
Selecting one of the Modules described below will open the Module I/O configuration menu
Monitor
Shortcut to the Monitor page described above.
A/D N
The A/D buttons, which become active if you have 1 or more AD8(P)modules installed in the Horus
unit, allow access to the Input controls. N being a number incrementing from 1 to 6 (when looking
from the rear of the unit number 1 is left top, 6 is bottom right) referring to which of the six slots the
module is being inserted in. Please see below for a description of the buttons available.
D/A N
The D/A buttons become active when 1 or more IOC-DA8(P) modules are installed in the Horus unit.
MADI 1-2
MADI 1 port comes as standard with each Horus. MADI 2 will be listed as “EMPTY” in Horus units
that are not fitted with the optional MADI expansion card
AES 1-3
Comes as standard. The AES buttons are active since this module is coming as standard (as the
MADI 1 module). Connectivity is over 3 D-SUB25 connectors providing 24 channel (12 AES pairs) of
AES-EBU I/O.