Installing additional Horus MADI Extension Module (MADM or MADS)
Before you get started
- Place your Horus unit on a hard and dry surface or mount it onto a 19” rack, and leave plenty
of room for air convection.
- In order to meet the EMC requirements of directives 89/336/EEC and 93/68/EEC, and in
order to obtain the high performance possible for the Horus unit, you must use correctly
shielded cables of good quality for all external connections when installing the Horus unit. For
the power connection, a normal unshielded power cable with a proper ground can be used.
- Make sure that your sound system is at a safe volume level.
Hardware Installation
This section will take you through installation of your Horus unit. We will describe how to mount the
I/O modules and the power, audio and digital cable connections that can be accessed on the rear
panel.
*PLEASE ENSURE THAT YOUR HORUS UNIT IS SWITCHED OFF BEFORE ATTEMPTING TO
CONNECT ANY CABLES TO THE UNIT.*
Installing Horus MADI Extension I/O procedure
The MADI extension packaging should include the MADI module along with; two BNC nuts, two
spacers and two screws.
1. Place the shutdown Horus unit on a dry steady horizontal surface. Remove all cables
(including the power cable) and unscrew the Horus top panel.
2. On the Back Panel unscrew the MADI cover plate above your current MADI 1 I/O Module
Unscrewed MADI cover plate