User manual
www.merging.com/horus Page 12 - 54
Horus User Manual
4. Set the DIP Switches as per table Legend indicated on the DA8 module card
Output Level (dBu)
+24 +18 +15 +12
1
ON ON
2
ON ON
3
ON ON
Switch
S1 to S8
4
ON ON
Output Level calibration Example:
Assume your operating Level is 21 dBu for 0 dBFS (typical of French Radio Broadcasters), you
should set the DIP Switches all OFF (DIP Switch positioned to the left, with respect to the picture
below) to set maximum Output Level to +24 dBu (since there is no 21 dBu hardware settings)
Once this is set and the DA modules are screwed back in place. Power up the Horus and go to the
Horus Setup Page>Module, select each D/A module for software calibration.
In this example case set the software attenuation to - 3 dB (see image below), so the overall result
ends up at 21 dBu for a Full Scale signal