Assembling the rack mount ears
Hapi is delivered with two rack mount ears for easy installation into a 19” rack.
The ears can be mounted either on the front or the rear of the device.
Installing the rack mount ears on the front panel
1. Turn off and unplug your Hapi
2. Unscrew the eight (8) M3x5 screws located on the side of the device (4 screws per side)
3. Place the rack mount ears on the side of Hapi, as shown in the pictures below
4. Fix the ears with the four (4) M3x8 screws delivered with the ears
Installing the rack mount ears on the rear panel
1. Turn off and unplug your Hapi
2. Place the rack mount ears on the side of Hapi, as shown in the pictures below
3. Fix the ears with the four (4) M3x8 screws delivered with the ears
Hapi recommended placement in Rack
Due to confined space in a Rack furniture, adequate spacing (and ordering) between multiple Hapi or
Horus units will play a significant role on the units temperature. Although Merging has spent
considerable time in optimizing the Hapi power consumption in every aspect possible, the units are still
drawing an average of 30W. The dissipation of the related heat produced by this consumption is
therefore highly dependent on the airflow and natural air convection around those units.
With highly loaded Horus units (more than 3 I/O Analog modules per unit) or Hapi units (2 I/O Analog
modules per unit), Merging recommends a free space of 2U above and below each unit to
ensure adequate cooling of the devices.