User manual
www.merging.com/horus Page 3 - 9
Horus Release Notes
Fixed. “Product type does not match” firmware update error
Fixed in Firmware version 23877:
*To upgrade to this firmware version and the ones above it is mandatory to first update your
Maintenance Mode to v29
New: First Hapi firmware support
Improvement: Firmware extension renamed: Horus firmware is a .horus and Hapi a .hapi file
Improvement: LTC discontinuity when locked to external source
Improvement. Avoid Horus blank boot TFT screen (maintenance mode 29>)
Fixed. PTP issue with Core Audio Driver (AES67)
Fixed. Potential Sampling Rate mismatch
Fixed in Firmware version 23165:
Fixed. Web Access: Meters page is broken/no longer working
Fixed. Mic Pre Amps gain control accuracy
Fixed in Firmware version 22862:
Fixed. Horus TimeCode reading issue
Improvement: New DA Filter option for lower latency Outputs choices between:
Sharp roll-off filter: Offers a flat frequency response up to 22kHz, within
0.2dB, which has the tradeoff of 36 samples latency. This mode was and still
is the default one.
Slow roll-off filter: Offers a low latency of 9 samples, with the tradeoff of a
gentle frequency response attenuation starting around 16kHz and reaching -
2.5dB at 22kHz
Fixed in Firmware version 22777:
Improvement: Page advanced: renamed System
Improvement: PTP lock improvements when multiple Horus are connected to a Switch
Improvement: Horus DSD headroom set to +6dB (details in Horus User Manual)
Improvement: The Mic/Line gain range has been increased from +0dB/+60dB to +0dB/+66dB
Improvement: Page Setup updates:
Cooling mode and Terminations have been moved to System Page
Button Advanced -> renamed System
Button System Info -> renamed Info
Fixed in Firmware version 22527:
Improvement: Screensaver Dark option
Improvement: Horus Dim display option now applied to Horus Power Led
Improvement: Phantom Power Safety feature
If a MAJOR (by MAJOR, we mean that the threshold of short-circuit detection
requires at least 10 Preamp inputs to be shorted simultaneously) 48V
Phantom Power Supply short circuit is detected, 48V is forced off on all A/D
channels. An error message will be displayed
Improvement: Horus RAVENNA support for different latency modes (samples)
Ultra Low (16 smp)
Extra low (32 smp)
(48smp) for AES67 support
Low (64 smp)
Fixed. AD module small clicks in gain adjustment when Low Cut is enabled
Fixed. Timestamp of the first sample of a frame was not correct causing a problem with the
RAVENNA ASIO Driver
Fixed. Horus MTC stream was not correct on minute changes, causing Third Party DAW (e.g.
Live and Reaper) MTC chase to be inaccurate at each minute edge.
Fixed. Horus Meters “Hot” and “Alignment” setting not applied