Specifications
RAVENNA ASIO & Core Audio Guide
RAVENNA ASIO & Core Audio : Merging RAVENNA ASIO Driver (PC)
3 - 14
Troubleshooting
RAVENNA ASIO Panel
Please close the DAW application before making changes. Restart the DAW after accepting the changes.
Note: Sampling Rate changes must be made on the Horus. The DAW will follow the
Horus sampling rate.
Buffer size recommendations
Merging recommends setting the buffer size to 256 samples.
Latency and clicks
Audible pops and clicks can occur when using some third-party audio interfaces or depending on the speed of the
processor. To avoid this problem increase the Hardware Buffer size for the device. You should aim for the lowest
possible I/O buffer size value that doesn't introduce clicks, pops, and crackles in the audio.
RAVENNA ASIO Latencies
R A V E N N A A S I O l a t e n c i e s
Sampling Rate Buffer Size Recommended
Not
Recommended
44.1 kHz 64 smpl √*
128 smpl √
256 smpl √
512 smpl √
1024 smpl √
48 kHz 64 smpl √*
128 smpl √
256 smpl √
512 smpl √
1024 smpl √
88.2 kHz 64 smpl √*
128 smpl √
256 smpl √
512 smpl √*
1024 smpl √*
96 kHz 64 smpl √*
128 smpl √
256 smpl √
512 smpl √*
1024 smpl √*
176.4 kHz 64 smpl √
128 smpl √
256 smpl √*
512 smpl √*
1024 smpl √*
192 kHz 64 smpl √
128 smpl √
256 smpl √*
512 smpl √*
1024 smpl √*
DXD(352.8/384kHz)
& DSD 64 smpl √
128 smpl √
256 smpl √*
512 smpl √*
1024 smpl √*
* Potential noise or clicks