Owner`s manual

SC 1000 TACHOMETER
22 eng
Tank Calibration
FILL TANK TO ½
THEN PRESS PLUS BUTTON
[SAVE]
30428
Fill the tank to 1/2 full. Press the "+" button to
save the calibration level to 1/2 full.
FILL TANK TO 3/4
THEN PRESS PLUS BUTTON
[SAVE]
30429
Fill the tank to 3/4 full. Press the "+" button to
save the calibration level to 3/4 full.
FILL TANK TO FULL
THEN PRESS PLUS BUTTON
[SAVE]
30430
Fill the tank to full. Press the "+" button to
save the calibration level to full.
TANK 2 INPUT
OIL TANK
CALIBRATION
[SAVE][DOWN]
[ UP ]
52652
Select the type of tank; not installed, fuel tank
2, water tank, or waste tank. Oil tank is only
available with the OptiMax outboard.
NOTE: All tanks can be calibrated as
described previously.
CALIBRATION–FUEL USED
1. Press and hold the "MODE/SELECT" and "+" buttons for
approximately seven seconds until "SCREENS" appear.
2. Press "MODE/SELECT" to advance through the screen
selections to the exit screen and press the "+" button to
enter Fuel Tank Calibration.
3. Press "MODE/SELECT" to advance through the selections
to Calibration–Fuel Used.
Fuel Used Calibration
(SKIP) (EDIT)
CALIBRATION
FUEL USED
52650
Selects how fuel used is calibrated. Press "+"
to select "EDIT" or "MODE/SELECT" to
bypass how the fuel used is calibrated.
[FUEL]
FUEL USED CAL :
ENTER MULTIPLIER,
OR REFUELED ?
[MULT]
30166
Selects how fuel used is calibrated with a
multiplier or with refueling. Press "–" to select
multiplier "MULT" or "+" to select refueling
"FUEL."