Owner`s manual
SC 1000 TACHOMETER
20 eng
Tachometer–Display Screens
(DOWN )
(SAVE)
( UP )
30242
OFFSET = F
SEA TEMP
O
Sea temperature sensor error correction.
Press "DOWN" or "UP."
DEPTH SCREEN ?
[ NO ]
[SAVE] [ YES ]
23984
The depth screen is displayed "YES" for on or
off "NO."
REMOTE SCREENS ?
[ NO ] [SAVE] [ YES ]
52645
Allows all SC1000 tachometers that are
enabled (YES) to show the same screen.
When station 1 tachometer has depth on the
screen, station 2 tachometer will show the
same screen.
[SAVE] [ YES ]
23621
HIGH RESOLUTION TRIM ?
[ NO ]
Enables the trim angle to be displayed in 0.1°
increments if "YES" is selected.
[SAVE] [ YES ]
23641
TRIM POPUP ?
[ NO ]
The trim display screen pops up when the
trim setting is changed if "YES" is selected.
[ NO ] [ YES ] [CAL ]
SCREENS
EXIT ?
52646
Select "NO" to go through the screen
selection again, "YES" to exit the screens, or
"CAL" to calibrate the tank levels. Refer to
Fuel Tank Calibration.
FUEL TANK CALIBRATION
1. Press and hold the "MODE/SELECT" and "+" buttons for
approximately seven seconds until "SCREENS" appear.
2. Press "MODE/SELECT" to advance through the selections
to the exit screen and press the "+" button to enter Fuel
Tank Calibration.
There are three methods for calibrating the fuel tank level
monitoring feature:
• Do nothing. The linear readout is based on raw sensor
values. This mode does not factor in irregular tank shapes.