Service manual

EDI DIAGNOSIS
SERVICE MANUAL NUMBER 22
90-860074--1 FEBRUARY 2002 Page 5E-5
Service Precautions
Observe the following when working on EDI equipped engines:
Before removing any ECM system component, disconnect the negative battery
cable.
Never start the engine without the battery cable terminal ends being solidly
connected.
Never separate the battery from the on-board electrical system while the engine is
operating.
Never separate the battery feed wire from the charging system while the engine is
operating.
When charging the battery, disconnect it from the boats electrical system.
Ensure that all cable harnesses are connected solidly and that battery connections
are thoroughly clean.
Never connect or disconnect the wiring harness at the ECM when the ignition is
switched ON.
Before attempting any electric arc welding, disconnect the battery leads and the
ECM connectors.
When steam cleaning engines, Do NOT direct the steam cleaning nozzle at ECM
system components. If this happens, corrosion of the terminals or damage of
components can take place.
Use only the test equipment specified in the diagnostic charts, since other test
equipment may either give incorrect results or damage good components.
All voltage measurements using a voltmeter require a digital voltmeter with a rating
of 10 megohms input impedance.