Service manual

CORROSION PROTECTION - ALL MODELS SERVICE MANUAL NUMBER 28
Page 7A-2 90-863160 MAY 2000
Specifications
Special Tools
DESCRIPTION PART NUMBER
MerCathode Reference Electrode Test 76675T1
Quicksilver VOA Meter* 91-93572
*If you do not already have this meter, use a digital multi-meter. Do NOT use a standard ana-
log meter as inaccurate readings will result.
IMPORTANT: Quicksilver Volt/OhmMeter 91-93572 and Multi-Meter DVA/Tester
91-99750 are no longer recommended for testing corrosion protection.
Lubricants / Sealants / Adhesives
DESCRIPTION PART NUMBER
Quicksilver Liquid Neoprene 92-25711-3
Continuity Circuit
Transom assembly and sterndrive unit are equipped with ground circuit wires to ensure
good electrical continuity between engine, transom assembly and sterndrive components.
Good continuity is essential for the Anode and MerCathode System to function most effec-
tively.
Inspect the following ground circuit components at intervals (Section 1B) for loose connec-
tions, broken or fraying wires.
22028
a
a-Steering Lever Ground Wire
INDEX