Service manual
SERVICE PROCEDURES REQUIRING MAJOR DISASSEMBLY
SERVICE MANUAL NUMBER 28
90-863160 MAY 2000 Page 4B-31
7. Clean shift cable bellows mounting flange on gimbal housing with sandpaper and wipe
clean with lacquer thinner.
76662
a
a-Mounting Flange
WARNING
Read and follow package label directions before using bellows adhesive.
8. Apply bellows adhesive to shift cable bellows mounting surface. Allow to dry until
adhesive is no longer tacky (approximately 10 minutes) before installing.
22454
a
a-Bellows Mounting Surface
9. Install shift cable bellows on gimbal housing flange. Position hose clamp as shown.
Torque to 35 lb-in. (4 Nm).
76663
a
b
a-Shift Cable Bellows
b-Hose Clamp
INDEX